English
Language : 

BTM7750GP Datasheet, PDF (12/18 Pages) Infineon Technologies AG – TrilithIC
BTM7750GP
5.4
Electrical Characteristics
ISH1 = ISH2 = ISL1 = ISL2 = 0 A; – 40 °C < Tj < 110 °C; 8 V < VS < 18 V
unless otherwise specified
Pos. Parameter
Symbol Limit Values
min. typ.
Current Consumption HS-switch
5.4.27 Quiescent current
IS
–
5
5.4.28 Supply current;
one HS-switch active
5.4.29 Supply current;
both HS-switches active
5.4.30 Leakage current of
high-side switch
5.4.31 Leakage current through logic GND
in free wheeling condition
Current Consumption LS-switch
5.4.32 Input current
–
IS
–
IS
–
ISH LK
–
ILKCL = IFH + –
ISH
IIL
–
–
1.65
3.3
–
–
8
–
160
5.4.33 Leakage current of low-side switch IDL LK
–
2
Under Voltage Lockout HS-switch
5.4.34 Switch-ON voltage
5.4.35 Switch-OFF voltage
5.4.36 Switch ON/OFF hysteresis
Output stages
VUVON
VUVOFF
VUVHY
–
–
1.8 –
–
1
5.4.37 Inverse diode of high-side switch; VFH
Forward-voltage
–
0.8
5.4.38 Inverse diode of low-side switch;
VFL
Forward-voltage
–
0.8
5.4.39 Static drain-source on-resistance of RDS ON H –
70
high-side switch
–
110
5.4.40 Static drain-source
RDS ON L
–
45
on-resistance of low-side switch
–
65
max.
9
12
3.3
6.6
6
10
30
300
10
4.8
3.5
–
1.2
1.2
–
165
–
100
Unit Test Condition
μA IH1 = IH2 = 0 V
Tj = 25 °C
μA IH1 = IH2 = 0 V1)
mA IH1 or IH2 = 5 V
VS = 12 V
mA IH1 and IH2 = 5 V
VS = 12 V
μA VIH = VSH = 0 V
VS = 12 V
mA IFH = 3 A
VS = 12 V
μA VIL = 5 V;
normal operation
μA VIL = 5 V;
failure mode
μA VIL = 0 V
VDSL = 18 V
V VS increasing
V VS decreasing
V
VUVON – VUVOFF
V IFH = 3 A
V IFL = 3 A
mΩ ISH = 1 A; VS = 12 V
Tj = 25 °C
mΩ ISH = 1 A; VS = 12 V
Tj = 110 °C1)
mΩ ISL = 1 A; VIL = 5 V
Tj = 25 °C
mΩ ISL = 1 A; VIL = 5 V
Tj = 110 °C1)
Data Sheet
12