Functional Description
4.3
Power-up and Undervoltage Condition
By detecting an undervoltage event, either on the transmitter supply VCC or the digital supply VIO, the transceiver
TLE7250X changes the mode of operation. Turning off the digital power supply VIO, the transceiver powers down
and remains in the power-down state. While switching off the transmitter supply VCC, the transceiver changes to
the forced power-save mode, (details see Figure 5).
VIO “on”
VCC “on”
RM “0”
normal-operating
mode
RM VCC VIO
0 “on” “on”
power-down
state
RM VCC VIO
“X” “X” “off”
VIO “on”
VCC “off”
RM “X”
VIO “on”
VCC “on”
RM “0”
VIO “on”
VCC “on”
RM “1”
VIO “on”
VCC “on”
RM “1”
receive-only
mode
RM VCC VIO
1 “on” “on”
VIO “on”
VCC “off”
RM “0”
VIO “on”
VCC “on”
RM “0”
forced power-save
mode
RM VCC VIO
“X” “off” “on”
VIO “on”
VCC “on”
RM “1”
VIO “on”
VCC “off”
RM “1”
Figure 5 Power-up and undervoltage
Table 2 Modes of operation
Mode
RM
VIO
VCC
Normal-operating “low” “on” “on”
Receive-only
“high” “on” “on”
Forced power-save “X”
“on”
“off”
Power-down state “X”
“off” “X”
Bus Bias Transmitter
VCC/2
“on”
VCC/2
“off”
floating “off”
floating “off”
Normal-mode Low-power
Receiver
Receiver
“on”
not available
“on”
not available
“off”
not available
“off”
not available
Data Sheet