TLE7250X Datasheet, PDF (11/34 Pages) Infineon Technologies AG – High Speed CAN-Transceiver | |||
|
◁ |
TLE7250XLE
TLE7250XSJ
Functional Description
4.3
Power-up and Undervoltage Condition
By detecting an undervoltage event, either on the transmitter supply VCC or the digital supply VIO, the transceiver
TLE7250X changes the mode of operation. Turning off the digital power supply VIO, the transceiver powers down
and remains in the power-down state. While switching off the transmitter supply VCC, the transceiver changes to
the forced power-save mode, (details see Figure 5).
VIO âonâ
VCC âonâ
RM â0â
normal-operating
mode
RM VCC VIO
0 âonâ âonâ
power-down
state
RM VCC VIO
âXâ âXâ âoffâ
VIO âonâ
VCC âoffâ
RM âXâ
VIO âonâ
VCC âonâ
RM â0â
VIO âonâ
VCC âonâ
RM â1â
VIO âonâ
VCC âonâ
RM â1â
receive-only
mode
RM VCC VIO
1 âonâ âonâ
VIO âonâ
VCC âoffâ
RM â0â
VIO âonâ
VCC âonâ
RM â0â
forced power-save
mode
RM VCC VIO
âXâ âoffâ âonâ
VIO âonâ
VCC âonâ
RM â1â
VIO âonâ
VCC âoffâ
RM â1â
Figure 5 Power-up and undervoltage
Table 2 Modes of operation
Mode
RM
VIO
VCC
Normal-operating âlowâ âonâ âonâ
Receive-only
âhighâ âonâ âonâ
Forced power-save âXâ
âonâ
âoffâ
Power-down state âXâ
âoffâ âXâ
Bus Bias Transmitter
VCC/2
âonâ
VCC/2
âoffâ
floating âoffâ
floating âoffâ
Normal-mode Low-power
Receiver
Receiver
âonâ
not available
âonâ
not available
âoffâ
not available
âoffâ
not available
Data Sheet
11