TLE4471_09 Datasheet, PDF (11/24 Pages) Infineon Technologies AG – Triple Voltage Regulator
TLE 4471
Table 4
Characteristics (cont’d)
VI = 13.5 V; Tj = -40 °C < Tj < 125 °C
Parameter
Symbol
Limit Values
Unit Measuring Condition
Min. Typ. Max.
Reset delay charging IDR, ch
2
46
µA VDR = 1 V
current
Reset delay
discharge current
IDR, dis
60 120 160 mA VDR = 1 V
Upper reset timing
threshold
VDR, dt
0.9 1.8 2.7 V –
Lower timing
threshold
VDR, st
0.25 0.4 0.65 V –
Reset delay time
tdr
Reset reaction time trr
Watchdog
35 50 70
0.5 – 3
ms CR = 100 nF
µs CR = 100 nF
Watchdog input
RW
pull-down resistor
5
15 40 kΩ –
Watchdog delay
charging current
IDW, ch
2
46
µA VDW = 1 V; VDR = 2.7 V
Watchdog upper
timing threshold
VDW, dt
1.5 1.9 2.5 V –
Watchdog lower
timing threshold
VDW, st
0
30 200 mV –
Watchdog trigger
twp
pulse interval
35 50 70 ms CDW = 100 nF
Reference Output REF2
Voltage divider ratio VREF2
Output impedance RREF2
Output clamp voltage –
49.5 50
10 –
–
–
50.5
20
4.5
% of –
VQ2
kΩ –
V–
Data Sheet
11
Rev. 1.6, 2009-02-03