ICE3BS02L Datasheet, PDF (11/21 Pages) Infineon Technologies AG – Off-Line SMPS Current Mode Controller with integrated 500V Startup Cell and Latched off Mode
F3
ICE3BS02L
Functional Description
within a wide range. Current Limiting is now possible in a
very accurate way.
E.g. Ipeak = 0.5A with RSense = 2. Without Propagation Delay
Compensation the current sense threshold is set to a static
voltage level Vcsth=1V. A current ramp of
dI/dt = 0.4A/µs, that means dVSense/dt = 0.8V/µs, and a
propagation delay time of i.e. tPropagation Delay =180ns leads
then to an Ipeak overshoot of 14.4%. By means of propagation
delay compensation the overshoot is only about 2% (see
Figure 12).
with an Adjustable Blanking Window which is depending on
the external Soft Start capacitor. By means of this Adjustable
Blanking Window, the IC avoids entering into these two
modes accidentally. Furthermore it also provides a certain
time whereby the overload detection is delayed. This delay
is useful for applications which normally works with a low
current and occasionally require a short duration of high
current.
3.6.1
Adjustable Blanking Window
V
1,3
1,25
1,2
1,15
1,1
1,05
1
0,95
0,9
0
with compensation
without compensation
0,2 0,4 0,6 0,8
1 1,2 1,4 1,6 1,8
dVSense
dt
2V
µs
SoftS
6.5V
5kΩ RSoftS
4.4V
1
S1
G2
Figure 12 Overcurrent Shutdown
The Propagation Delay Compensation is realized by means
of a dynamic threshold voltage Vcsth (see Figure 13). In case
of a steeper slope the switch off of the driver is earlier to
compensate the delay.
VOSC max. Duty Cycle
C3
5.4V
4.8V
C4
&
Auto
Restart
G5
Mode
off time
Active
Burst
Mode
VSense
Vcsth
Propagation Delay t
FB
C5
1.32V
&
G6
Control Unit
Signal1
Signal2
t
Figure 13 Dynamic Voltage Threshold Vcsth
3.6
Control Unit
The Control Unit contains the functions for Active Burst
Mode, Auto Restart Mode and Latched Off Mode. The
Active Burst Mode and the Auto Restart Mode are combined
Figure 14 Adjustable Blanking Window
VSoftS is clamped at 4.4V by the closed switch S1 after the
SMPS is settled. If overload occurs VFB is exceeding 4.8V.
Auto Restart Mode can’t be entered as the gate G5 is still
blocked by the comparator C3. But after VFB has exceeded
4.8V the switch S1 is opened via the gate G2. The external
Soft Start capacitor can now be charged further by the
integrated pull up resistor RSoftS. The comparator C3 releases
the gates G5 and G6 once VSofts has exceeded 5.4V.
Therefore there is no entering of Auto Restart Mode possible
during this charging time of the external capacitor CSoftS. The
Version 1.1
11
28 Sep 2005