English
Language : 

TLE4955C Datasheet, PDF (10/21 Pages) Infineon Technologies AG – Differential Hall Effect Transmission Speed Sensors
Confidential
TLE4955C
Operating Range
5
Operating Range
All parameters specified in the following sections refer to these operating conditions unless otherwise
noticed. For further details please refer also to any relevant Application Notes.
Table 3 Operating Range
Parameter
Symbol
Values
Unit Note or Test Condition
Min. Typ. Max.
Supply voltage
VDDIC
4
Supply voltage modulation VAC
20 V Directly on the IC leads
6
V VDD = 13 V; 0< fmod < 150 kHz1) peak-to-
peak
Operating junction
temperature
Tj
either
-40
110 °C 12500 h
or
125 °C 10000 h
or
150 °C 5000 h
or
160 °C 2500 h
or
170 °C 500 h
Junction temperature
Tj_var
-60
variation between two
consecutive magnetic
edges3)
Frequency range of
f
0
magnetic input signal2)
Bias-induction3)
Bo
-500
Differential bias-induction3) ΔBstat l/r
-30
60 K Values apply for ΔBspeed and ΔBdir > 2.5mT
(amplitude) in calibrated mode. In case of
uncalibrated sensor, values apply for
ΔBspeed and ΔBdir > 7.5mT (amplitude).
12 kHz
+500 mT
+30 mT
Magnetic bias induction at the position of
each sensing element (B1, B2, B3)
Difference of the magnetic bias induction
between left (B1) and right (B2) sensing
element
Differential bias-induction ΔBstat m/o -30
between mean value at left,
right and center sensing
elements3)
+30 mT Difference of the magnetic bias induction
between (B2+B1)/2 and B3
Speed signal range
ΔBspeed,range -120
120 mT
Minimum speed signal
ΔBspeed- limit 0.6 1.1 2.0 mT
Minimum direction signal ΔBdir-limit 0.1 0.18 0.36 mT
1) Sine wave.
2) No time based watchdog.
3) Not subject to production test, verified by design/characterization.
4) 99% criterion stands for 1 out of 100 pulses is missing.
Amplitude value, 99% criteria4)
Amplitude value, 99% criteria3)4)
Note:
Magnetic parameters are valid for sinusoidal signals and characterized for f > 1 Hz.
Data Sheet
10
Version 1.0
2016-06-15