Data Sheet TLE 6230 GP
A definite distinction between open load and short to ground is guaranteed by design.
The standard way of obtaining diagnostic information is as follows:
Clock in serial information into SI pin and wait approximately 150 µs to allow the outputs toset-
tle. Clock in the identical serial information once again - during this process the data coming
out at SO contains the bit combinations representing the diagnosis conditions as described in
figure 1.
By means of the control byte it is possible either to:
a) control the eight outputs according to the data byte, as well as being able to read the
diagnostic information
or b) purely get diagnostic information without changing the state of the outputs.
a) Serial Control of Outputs
H1H4H4H2H4HH43H L1H4L4H2H4LL43L : Serial input information
Control Byte
Data Byte
Control byte is set to FFhex: Data byte will be accepted. The outputs will be switched ON or
OFF according to the information of the data byte and the parallel inputs (Channel 1 to 4 be-
cause of AND operation).
All other control words except the one for 'Diagnosis Only = 00hex' will also be accepted as a
valid control word and the data will be accepted.
Example: HLLHLHLH DDDDDDDD: Outputs will switch according to the data bits.
b) Diagnosis Only
L1L4L4L2LL4L43L X1X4X4X2X4XX43X : Serial input information
Control Byte
Data Byte
Control byte is set to 00hex: Data byte will be ignored. Diagnostic information can be read out
at any time with no change of the switching conditions. Only 00hex means 'Diagnosis Only'.
V2.3
Page 10
18. Nov. 2009