IL2904
M AXI M UM RATI NGS*
Symbol
Parameter
Value
Unit
VCC Power Supply Voltages
Single Supply
Split Supplies
32
V
±16
VIDR Input Differential Voltage Range (1)
VICR Input Common Mode Voltage Range
I SC
Output Short Circuit Duration
TJ
Junction Temperature
Plastic Packages
±32
V
-0.3 to 32
V
Continuous
150
°C
Tstg Storage Temperature
°C
Plastic Packages
-55 to + 125
IIN
Input Current, per pin (2)
50
mA
TL
Lead Temperature, 1mm from Case for 10 Seconds
260
°C
* Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device.
These are stress ratings only and functional operation of the device at these or any other conditions beyond those
indicated under “recommended operating conditions” is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Functional operation should be restricted to the Recommended Operating Conditions.
+ Derating - Plastic DIP: - 10 mW/°C from 65° to 125°C
SOIC Package: : - 7 mW/°C from 65° to 125°C
Notes:
1. Split Power Supplies.
2. VIN< -0.3V. This input current will only exist when voltage at any of the input leads is driven negative.
RECOM M ENDED OPERATI NG CONDI TI ONS
Symbol
Parameter
V CC
DC Supply Voltage
TA
Operating Temperature, All Package Types
Min
M ax
Unit
±2.5 ±15 or
V
or 5.0 30
-40
+ 85
°C
This device contains protection circuitry to guard against damage due to high static voltages or electric
fields. However, precautions must be taken to avoid applications of any voltage higher than maximum rated voltages
to this high-impedance circuit. For proper operation, VIN and VOUT should be constrained to the range GND≤(VIN or
V OUT)≤V CC.
Unused inputs must always be tied to an appropriate logic voltage level (e.g., either GND or VCC). Unused
outputs must be left open.