ABSOLUTE MAXIMUM RATINGS
821024 DATA SHEET
RECOMMENDED DC OPERATING
CONDITIONS
NOTE: MCLK: 2.048 MHz, 4.096 MHz or 8.192 MHz with tolerance of ± 50 ppm
NOTE: Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation of the
device at these or any other conditions above those indicated in the operational sections of
this specification is not implied. Exposure to absolute maximum rating conditions for extended
periods may affect reliability.
ELECTRICAL CHARACTERISTICS
Digital Interface
Note: Total current must not exceed absolute maximum ratings.
Power Dissipation
Note: Power measurements are made at MCLK = 4.096 MHz, outputs unloaded
Analog Interface