Table 5B. AC Characteristics, VDD = 2.5V ± 5%, TA = -40°C to 85°C
Parameter
Symbol
Test Conditions
fMAX
tpLH
Output Frequency
Propagation Delay, Low-to-High;
NOTE 1
tjit
Buffer Additive Phase Jitter, RMS;
refer to Additive Phase Jitter Section
155.52MHz, Integration
Range: 12kHz – 20MHz
tsk(i)
Input Skew
tsk(pp)
Part-to-Part Skew; NOTE 2, 3
tR / tF
odc
Output Rise/Fall Time
Output Duty Cycle; NOTE 4
20% to 80%
f ≤ 200MHz
f = 250MHz
MUXISOLATION MUX Isolation
155.52MHz
Minimum Typical Maximum Units
250
MHz
1.5
2.7
ns
0.32
ps
195
ps
600
ps
80
600
ps
46
54
%
40
60
%
43
dB
NOTE 1: Measured from VDD/2 of the input to VDD/2 of the output.
NOTE 2: Defined as skew between outputs on different devices operating at the same supply voltage and with equal load conditions.
Using the same type of inputs on each device, the outputs are measured at the differential cross points.
NOTE 3: This parameter is defined according with JEDEC Standard 65.
NOTE 4: Input duty cycle must be 50%.
IDT™ / ICS™ 12:1, SINGLE-ENDED MULTIPLEXER
6
ICS850S1201BGI REV. A AUGUST 15, 2008