853S058 DATA SHEET
AC Electrical Characteristics
Table 5. AC Characteristics, VCC = 0V, VEE = -3.465V to -2.375V or VCC = 2.375 to 3.465V, VEE = 0V, TA = -40°C to 85°C
Symbol
Parameter
Test Conditions
Minimum
Typical
Maximum Units
fOUT
tjit
Output Frequency
Buffer Additive Phase Jitter,
RMS; refer to Additive Phase
Jitter section
155.52MHz, Integration Range:
12kHz – 20MHz
0.075
2.5
GHz
ps
tPD
Propagation Delay;
NOTE 1
250
600
ps
tsk(pp)
Part-to-Part Skew;
NOTE 2, 3
350
ps
tsk(i)
Input Skew
75
ps
tR / tF
Output Rise/Fall Time
MUXISOLATION MUX Isolation; NOTE 4
20% to 80%
75
155.52MHz,
Input Peak-to-Peak = 800mV
250
ps
90
dB
NOTE: Electrical parameters are guaranteed over the specified ambient operating temperature range, which is established when the device is
mounted in a test socket with maintained transverse airflow greater than 500 lfpm. The device will meet specifications after thermal equilibrium
has been reached under these conditions.
NOTE: All parameters measured  1.0GHz, unless otherwise noted.
NOTE 1: Measured from the differential input crossing point to the differential output crossing point.
NOTE 2: Defined as skew between outputs on different devices operating at the same supply voltage and with equal load conditions. Using the
same type of inputs on each device, the outputs are measured at the differential cross points.
NOTE 3: This parameter is defined according with JEDEC Standard 65.
NOTE 4: Q, nQ output measured differentially. See Parameter Measurement Information for MUX Isolation diagram.
REVISION B 1/6/15
5
8:1 DIFFERENTIAL-TO-3.3V OR 2.5V LVPECL/ECL