AC Characteristics
Table 3. AC Characteristics, VCC = 2.5V-5% to VCC = 3.3V+10%, VEE = 0V, TA = -40°C to 85°C
Symbol
Parameter
Test Conditions
Minimum
Typical
fREF
tPD
tsk(p)
Input Reference Frequency
Propagation Delay, NOTE 1
Output Pulse Skew
VCC = 3.3V
VCC = 2.5V
75
135
85
130
tsk(o)
tsk(pp)
Output Skew, NOTE 2, 3
Part-to-Part Skew, NOTE 3, 4
VCC = 3.3V
VCC = 2.5V
odc
Output Duty Cycle
47
tjit
Buffer Additive Phase Jitter,
RMS; Refer to Additive Phase
Jitter Section
122.88MHz,
Integration Range:10Hz – 10MHz
45
122.88MHz, Offset: 10Hz
-98
122.88MHz, Offset: 100Hz
-128
Phase Noise Frequency
Offset
122.88MHz, Offset: 1kHz
122.88MHz, Offset: 10kHz
-150
-158
122.88MHz, Offset: 100kHz
-161
122.88MHz, Offset: >1MHz
-161
Power Supply Rejection;
NOTE 5
VCC = 3.3V
3
tR / tF
Output Rise/Fall Time
VCC = 3.3V, 20% to 80%
VCC = 2.5V, 20% to 80%
90
110
Maximum
3
175
200
15
10
17
50
53
Units
GHz
ps
ps
ps
ps
ps
ps
%
fs
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
ps/V
135
ps
170
ps
NOTE: Electrical parameters are guaranteed over the specified ambient operating temperature range, which is established when the device
is mounted in a test socket with maintained transverse airflow greater than 500 lfpm. The device will meet specifications after thermal
equilibrium has been reached under these conditions.
NOTE: All parameters characterized at fREF  2GHz, unless noted otherwise.
NOTE 1: Measured from the differential input crossing point to the differential output crosspoint.
NOTE 2: Defined as skew between outputs at the same supply voltage and with equal load conditions. Measured at the output differential
crosspoints.
NOTE 3: This parameter is defined according with JEDEC Standard 65.
NOTE 4: Defined as skew between outputs on different devices operating at the same supply voltage, same temperature, same frequency
and with equal load conditions. Using the same type of inputs on each device, the outputs are measured at the differential crosspoints.
NOTE 5: Change in tPD per change in VCC.