IDT82V2108 T1 / E1 / J1 OCTAL FRAMER
7.7.3 RECEIVE & TRANSMIT LINE TIMING
INDUSTRIAL
TEMPERATURE RANGES
Note that timing information can refer to the positive or negative edge of the reference clock. The active clock edge is selected by configuration
flags.
7.7.3.1 Receive Line Interface Timing
Symbol
Ts
Th
Parameter
Setup Time
Hold Time
Min
Typ
Max
Unit
10
ns
10
ns
LRCK[x]
LRD[x]
Ts
Thold
Figure - 91. Receive Line Interface Timing
7.7.3.2 Transmit Line Interface Timing
Symbol
Tprop
Parameter
Propagation delay
Min
Typ
-10
Max
Unit
10
ns
TLCLK[x]
Tprop
TLD[x]
Figure - 92. Transmit Line Interface Timing
271