Figure 3.2 Operational Flow Chart: Command Mode and Normal Mode
Start LV
Get command from HV
CMD==Start_CM
no
Case (Command)
INVALID_CMD
REGULAR_CMD
Execute: Command
CM active
yes
Receive: Command
INVALID_CMD
Case (Command)
Start_NOM
CM inactive
REGULAR_CMD
Execute: Command
End LV
Sleep Mode
Command Mode
Color Legend:
LV-Operation
HV-Operation
3.4. Command Interpretation
3.4.1. SPI/I2C™ Commands
The user-accessible section of memory includes addresses 00HEX through 17HEX in the OTP memory that is
designated by the user memory page pointer. Because each of the four OTP memory pages cannot be rewritten
or erased, the memory page pointer must be incremented to the next OTP memory page in order to write to
memory again (see Table 3.1 for the command). After all four user-accessible OTP memory pages have been
used, further write operations are not possible and the “Memory Full” bit is returned as set in the status byte after
write operations (see section 3.5.1).
© 2016 Integrated Device Technology, Inc.
22
April 20, 2016