English
Language : 

ICS9248-77 Datasheet, PDF (9/14 Pages) Integrated Circuit Systems – Frequency Timing Generator for PENTIUM II Systems
ICS9248-77
Absolute Maximum Ratings
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.0V
Logic Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND –0.5 V to VDD +0.5 V
Ambient Operating Temperature . . . . . . . . . . . . 0°C to +70°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . –65°C to +150°C
Case Temperature . . . . . . . . . . . . . . . . . . . . . . . . 115°C
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. These ratings are
stress specifications only and functional operation of the device at these or any other conditions above those listed in the
operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods
may affect product reliability.
Electrical Characteristics - Input/Supply/Common Output Parameters
TA = 0 - 70º C; VDD, VDDL = 3.3 V +/-5% (unless otherwise stated)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Input High Voltage
Input Low Voltage
Input High Current
Input Low Current
Input Low Current
Operating Supply
VIH
VIL
IIH
IIL1
IIL2
IDD3.3OP 100
VIN = VDD
VIN = 0 V; Inputs with no pull-up resistors
VIN = 0 V; Inputs with pull-up resistors
CL = 0 pF; Select @ 100 MHz
2
VDD+0.3 V
VSS-0.3
0.8
V
0.1
5
µA
-5 2.0
µA
-200 -100
µA
81 160 mA
Current
IDD3.3OP133 CL = 0 pF; Select @ 133 MHz
85 160 mA
Input frequency
Fi
VDD = 3.3 V;
11 14.318 16 MHz
Input Capacitance1
Transition Time1
Settling Time1
Clk Stabilization1
CIN
CINX
Ttrans
Ts
TSTAB
Logic Inputs
X1 & X2 pins
To 1st crossing of target Freq.
From 1st crossing to 1% target Freq.
From VDD = 3.3 V to 1% target Freq.
5
pF
27 36
45
pF
3
ms
5
3
ms
3
ms
1Guaranteed by design, not 100% tested in production.
Electrical Characteristics - Input/Supply/Common Output Parameters
TA = 0 - 70º C; VDD = 3.3 V +/-5%; VDDL = 2.5 V +/-5% (unless otherwise stated)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Operating
IDD2.5OP100 CL = 0 pF; Select @ 100 MHz
16
75 mA
Supply Current
IDD2.5OP133 CL = 0 pF; Select @ 133 MHz
19
90 mA
Power Down Supply Current IDD2.5PD CL = 0 pF; PWRDWN# = 0
0.1 100 µA
1Guaranteed by design, not 100% tested in production.
9