English
Language : 

ICS83056I Datasheet, PDF (6/13 Pages) Integrated Circuit Systems – 6:1, SINGLE-ENDED MULTIPLEXER
Integrated
Circuit
Systems, Inc.
ICS83056I
6:1, SINGLE-ENDED MULTIPLEXER
TABLE 5D. AC CHARACTERISTICS, VDD = VDDO = 2.5V ± 5%, TA = -40°C TO 85°C
Symbol Parameter
Test Conditions
Minimum Typical Maximum Units
fMAX
tpLH
tpHL
tsk(i)
Output Frequency
Propagation Delay, Low to High; NOTE 1
Propagation Delay, High to Low; NOTE 1
Input Skew; NOTE 2
250
MHz
2.5
3.0
3.5
ns
2.5
2.9
3.4
ns
60
175
ps
tsk(pp) Part-to-Part Skew; NOTE 2, 3
300
ps
t /t
RF
odc
Output Rise/Fall Time
Output Duty Cycle
20% to 80%
100
40
500
ps
60
%
MUXISOL MUX Isolation
@ 100MHz
45
dB
NOTE 1: Measured from VDD/2 of the input to VDDO/2 of the output.
NOTE 2: This parameter is defined in accordance with JEDEC Standard 65.
NOTE 3: Defined as skew between outputs on different devices operating a the same supply voltages and
with equal load conditions. Using the same type of input on each device, the output is measured at VDDO/2.
TABLE 5E. AC CHARACTERISTICS, VDD = 2.5V ± 5%, VDDO = 1.8V ± -0.2V, TA = -40°C TO 85°C
Symbol Parameter
Test Conditions
Minimum Typical Maximum
fMAX
tpLH
tpHL
tsk(i)
Output Frequency
Propagation Delay, Low to High; NOTE 1
Propagation Delay, High to Low; NOTE 1
Input Skew; NOTE 2
250
2.6
3.3
4.0
2.7
3.3
4.0
50
150
tsk(pp) Part-to-Part Skew; NOTE 2, 3
325
tR / tF
odc
Output Rise/Fall Time
Output Duty Cycle
20% to 80%
100
700
40
60
MUXISOL MUX Isolation
@ 100MHz
45
NOTE 1: Measured from VDD/2 of the input to VDDO/2 of the output.
NOTE 2: This parameter is defined in accordance with JEDEC Standard 65.
NOTE 3: Defined as skew between outputs on different devices operating a the same supply voltages and
with equal load conditions. Using the same type of input on each device, the output is measured at VDDO/2.
Units
MHz
ns
ns
ps
ps
ps
%
dB
83056AGI
www.icst.com/products/hiperclocks.html
6
REV. A JANUARY 18, 2006