ICS93V8 5 7 - X X X
Recommended Operating Condition (see note1)
TA = 0 - 85°C; Supply Voltage AVDD, VDD = 2.5 V +/- 0.2V (unless otherwise stated)
PARAMETER
SYMBOL
CONDITIONS
MIN
Supply Voltage
Low level input voltage
VDDQ, AVDD
2.3
CLK_INT, CLK_INC, FB_INC,
VIL FB_INT
PD#
-0.3
High level input voltage
VIH
CLK_INT, CLK_INC, FB_INC,
FB_INT
VDD/2 + 0.18
PD#
1.7
DC input signal voltage
(note 2)
VIN
-0.3
Differential input signal
voltage (note 3)
DC - CLK_INT, CLK_INC,
0.36
VID
FB_INC, FB_INT
AC - CLK_INT, CLK_INC,
0.7
FB_INC, FB_INT
Output differential cross-
voltage (note 4)
VOX
VDD/2 - 0.15
Input differential cross-
voltage (note 4)
VIX
VDD/2 - 0.2
High level output current
Low level output current
High Impedance
Output Current
IOH
IOL
IOZ
VDD=2.7V, VOUT=VDD or GND
Operating free-air
temperature
TA
0
TYP
2.5
0.4
2.1
VDD/2
0.1
MAX
2.7
UNITS
V
VDD/2 - 0.18 V
0.7
V
V
VDD + 0.6
V
VDD + 0.3
V
VDD + 0.6
V
VDD + 0.6
V
VDD/2 + 0.15 V
VDD/2 + 0.2 V
-12
mA
12
mA
±10
mA
85
°C
Notes:
1. Unused inputs must be held high or low to prevent them from floating.
2. DC input signal voltage specifies the allowable DC execution of differential input.
3. Differential inputs signal voltages specifies the differential voltage [VTR-VCP]
required for switching, where VTR is the true input level and VCP is the
complementary input level.
4. Differential cross-point voltage is expected to track variations of VDD and is the
voltage at which the differential signal must be crossing.
0693K—03/13/03
4