External Components
The ICS554-01 requires a decoupling capacitor of 0.01µF to be connected between VDD on pin 2 and
GND on pin 7, as well as between VDD on pin 15 and GND on pin 10. These decoupling capacitors should
be placed as close to the device as possible. A 0.01µF capacitor must be placed between the RES (pin 16)
and Ground, also, a resistor must be connected between the RES (pin 16) and VDD. Another eight
resistors are needed for the PECL outputs as shown on the block diagram on page 1. Suggested values of
these resistors are shown in the Block Diagram, but they can be varied to change the differential pair
output swing, and the DC level. Refer to Application Note, MAN09.
To achieve the low output skews that the ICS554-01 is capable of, careful attention must be paid to board
layout. Essentially, all 8 outputs must have identical terminations, identical loads, and identical trace
geometries. If they do not, the output skew will be degraded. For example, using a 30Ω series termination
on one output (with 33Ω on the others) will cause at least 15ps of skew.
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS554-01. These ratings,
which are standard values for ICS commercially rated parts, are stress ratings only. Functional operation of
the device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Item
Supply Voltage, VDD
All Inputs and Outputs
Ambient Operating Temperature
Storage Temperature
Junction Temperature
Soldering Temperature
Rating
7V
-0.5V to VDD+0.5V
0 to +70°C
-65 to +150°C
175°C
260°C
Recommended Operation Conditions
Parameter
Ambient Operating Temperature
Power Supply Voltage (measured in respect to GND)
Min.
0
+3.15
Typ.
–
Max.
+70
+5.25
Units
°C
V
MDS 554-01 A
3
Revision 031901