English
Language : 

ICS508 Datasheet, PDF (3/5 Pages) Integrated Circuit Systems – PECL to CMOS Converter
PRELIMINARY INFORMATION
ICS508
PECL to CMOS Converter
Electrical Specifications
Parameter
Conditions
Minimum Typical Maximum Units
ABSOLUTE MAXIMUM RATINGS (stresses beyond these can permanently damage the device)
Supply Voltage, VDDP and VDDC
Referenced to GND
PECL Inputs
Referenced to GND
-0.5
Clock Output and OE Pin
Referenced to GND
-0.5
Ambient Operating Temperature
0
ICS508MI only
-40
Soldering Temperature
Max of 10 seconds
Storage temperature
-65
7
V
VDDP+0.5 V
VDDC+0.5 V
70
°C
85
°C
260
°C
150
°C
DC CHARACTERISTICS (VDDP = VDDC = 3.3 V unless otherwise noted)
Operating Voltage, VDDP
Note 1
3
5.5
V
Operating Voltage, VDDC
Note 1
2.375
5.5
V
Peak to Peak Input Voltage, PECLIN
0.3
1
V
Common Mode Range, PECLIN
VDDP = 5 V
VDDP - 3.7
VDDP - 0.6 V
Common Mode Range, PECLIN
VDDP = 3.3 V
VDDP - 2.0
VDDP - 0.6 V
Input High Voltage, VIH
OE only
2
VDDC
V
Input Low Voltage, VIL
OE only
0.8
V
Output High Voltage, VOH
VDDC = 5 V, IOH = -24 mA VDDC-0.4
V
Output High Voltage, VOL
VDDC = 5 V, IOL = 24 mA
0.4
V
Output High Voltage, VOH
VDDC = 3.3 V, IOH = -18 mA VDDC-0.4
V
Output High Voltage, VOL
VDDC = 3.3 V, IOL = 18 mA
0.4
V
Output High Voltage, VOH
VDDC = 2.5 V, IOH = -8 mA VDDC-0.4
V
Output High Voltage, VOL
VDDC = 2.5 V, IOL = 8 mA
0.4
V
On-Chip Pull-up Resistor
OE
250
kΩ
Operating Supply Current, IDDP
100 MHz, no load
1.5
mA
Operating Supply Current, IDDC
100 MHz, no load
8
mA
Note 1: VDDP must alwa s be greater than or equal to VDDC.
MDS 508 C
3
Revision 012400
Printed 11/13/00
Integrated Circuit Systems, Inc. • 525 Race Street • San Jose •CA•95126•(408) 295-9800tel • www.icst.com