English
Language : 

X76F400 Datasheet, PDF (9/14 Pages) IC MICROSYSTEMS – Secure SerialFlash
X76F400
EQUIVALENT A.C. LOAD CIRCUIT
Output
5V
1.53KΟ
100pF
Output
3V
1.3KΟ
100pF
A.C. TEST CONDITIONS
Input pulse levels
Input rise and fall times
Input and output timing level
Output load
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
100pF
AC CHARACTERISTICS (TA = -40°C to +85°C, VCC = +2.5V to +5.5V, unless otherwise specified)
Symbol
fSCL
tAA(2)
tBUF
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR
tF
tSU:STO
tDH
tNOL
tRDV
tCDV
tRST
tSU:RST
Parameter
SCL clock frequency
SCL LOW to SDA data out valid
Time the Bus must be free before a new transmission can start
Start condition hold time
Clock LOW period
Clock HIGH period
Start condition setup time (for a repeated start condition)
Data in hold time
Data in setup time
SDA and SCL rise time
SDA and SCL fall time
Stop condition setup time
Data out hold time
RST to SCL non-overlap
RST LOW to SDA valid during response to reset
CLK LOW to SDA valid during response to reset
RST high time
RST setup time
Min.
0
0.1
1.2
0.6
1.2
0.6
0.6
10
100
20+0.1XC b(1)
20+0.1XC b(1)
0.6
0
500
0
0
1.5
500
Max.
1
0.9
300
300
450
450
Unit
MHz
µs
µs
µs
µs
µs
µs
ns
ns
ns
ns
µs
µs
ns
ns
ns
µs
ns
Notes: (1)Cb = total capacitance of one bus line in pF
(2)tAA = 1.1µs Max below VCC = 2.5V.
RESET AC SPECIFICATIONS
Power Up Timing
Symbol
tPUR(1)
tPUW(1)
Parameter
Time from power up to read
Time from power up to write
Min.
Typ.(2)
Max.
1
5
Unit
ms
ms
Notes: (1)Delays are measured from the time VCC is stable until the specified operation can be initiated. These parameters are periodically sampled
and not 100% tested.
(2)Typical values are for TA = 25°C and VCC = 5.0V
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice. 9 of 14