ABSOLUTE MAXIMUM RATINGS
Temperature under bias....................–65°C to +135°C
Storage temperature ........................–65°C to +150°C
Voltage on any pin with
respect to V SS ......................................... –1V to +7V
D.C. output current............................................... 5mA
Lead temperature (soldering, 10 seconds).........300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
–40°C
Max.
+70°C
+85°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification) is not
implied. Exposure to absolute maximum rating conditions
for extended periods may affect device reliability.
Supply Voltage
X76F400
X76F400 – 2.5
Limits
4.5V to 5.5V
2.5V to 5.5V
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
I CC1
ICC2(3)
ISB1(1)
ISB2(1)
ILI
ILO
VIL(2)
VIH(2)
VOL
Parameter
VCC Supply current
(Read)
Limits
Min.
Max.
1
VCC Supply current
3
(Write)
VCC Supply current
1
(Standby)
VCC Supply current
1
(Standby)
Input leakage current
10
Output leakage current
Input LOW voltage
Input HIGH voltage
Output LOW voltage
–0.5
VCC x 0.9
10
VCC x 0.1
VCC + 0.5
0.4
Unit
mA
mA
µA
µA
µA
µA
V
V
V
Test Conditions
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 400 kHz,
SDA = Open
RST = V SS
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 400 kHz,
SDA = Open
RST = V SS
VIL = VCC x 0.1, VIH = VCC x 0.9
fSCL = 400 kHz, fSDA = 400 kHz
VSDA = VSCC = VCC
Other = GND or VCC–0.3V
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
Test
COUT(3)
CIN(3)
Output capacitance (SDA)
Input capacitance (RST, SCL)
Max.
8
6
Unit
pF
pF
Conditions
VI/O = 0V
VIN = 0V
Notes: (1)Must perform a stop command after a read command prior to measurement (2)V
IL min. and VIH max. are for reference only and are not tested
(3)This parameter is periodically sampled and not 100% test
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice. 8 of 14