English
Language : 

X24C02 Datasheet, PDF (9/16 Pages) Xicor Inc. – Serial E2PROM
X24C02
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to V SS ................................ –1.0V to +7.0V
D.C. Output Current ............................................ 5 mA
Lead Temperature (Soldering, 10 Seconds) ..... 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is not
implied. Exposure to absolute maximum rating conditions
for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
Industrial
Military
0°C
–40°C
–55°C
70°C
+85°C
+125°C
3838 PGM T09
Supply Voltage
X24C02
X24C02-3.5
X24C02-3
X24C02-2.7
Limits
4.5V to 5.5V
3.5V to 5.5V
3V to 5.5V
2.7 to 5.5V
3838 PGM T10
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified).
Symbol
lCC1
lCC2
ISB(1)
ISB(2)
ILI
ILO
VlL(2)
VIH(2)
VOL
Parameter
Power Supply Current (read)
Power Supply Current (write)
Standby Current
Limits
Min.
Max.
1
2
50
Standby Current
30
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
10
10
–1.0 VCC x 0.3
VCC x 0.7VCC + 0.5
0.4
Units
Test Conditions
mA SCL = VCC x 0.1/VCC x 0.9 Levels @ 100
KHz, SDA = Open, All Other
Inputs = GND or VCC – 0.3V
∝A SCL = SDA = VCC – 0.3V, All other
Inputs = GND or VCC, VCC = 5.5V
∝A SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC = 3.3V + 10%
∝A VIN = GND to VCC
∝A VOUT = GND to VCC
V
V
V IOL = 3 mA
3838 PGM T02
CAPACITANCE TA = 25°C, f = 1 MHz, VCC = 5V
Symbol
Parameter
C (3)
I/O
CIN(3)
Input/Output Capacitance (SDA)
Input Capacitance (A0, A1, A2, SCL, WC)
Notes:(1)Must perform a stop command prior to measurement.
(2)VIL min. and VIH max. are for reference only and are not tested. (3)This
parameter is periodically sampled and not 100% tested.
Max.
8
6
Units
pF
pF
Test Conditions
VI/O = 0V
VIN = 0V
3838 PGM T04
9