ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias
X24165 .......................................–65°C to +135°C
Storage Temperature ........................–65°C to +150°C
Voltage on any Pin with
Respect to VSS .................................... –1V to +7V
D.C. Output Current ..............................................5mA
Lead Temperature (Soldering, 10 Seconds) ...... 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum”
Ratings” may cause permanent damage to the device. This is
a stress rating only and the functional operation of the device
at these or any other conditions above those indicated in
the operational sections of this specification is not implied.
Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
0°C
+70°C
Industrial
Military
–40°C
–55°C
+85°C
+125°C
6551 FRM T04
D.C. OPERATING CHARACTERISTICS
Supply Voltage
X24165
X24165-2.7
Limits
4.5V to 5.5V
2.7V to 5.5V
6551 FRM T05
Limits
Symbol
ICC1
ICC2
Parameter
VCC Supply Current (Read)
VCC Supply Current (Write)
ISB1 (1)
VCC Standby Current
Min.
ISB2 (1)
VCC Standby Current
ILI
ILO
VlL (2)
VIH (2)
VOL
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
–1
VCC x 0.7
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Max.
1
3
50
1
10
10
VCC x 0.3
Units
Test Conditions
mA SCL = VCC X 0.1/VCC X 0.9 Levels @
mA 100KHz, SDA = Open, All Other
Inputs = VSS or VCC – 0.3V
∝A SCL = SDA = VCC, All Other
Inputs = VSS or VCC – 0.3V,
VCC = 5V ± 10%
∝A SCL = SDA = VCC, All Other
Inputs = VSS or VCC – 0.3V,
VCC = 2.7V
∝A VIN = VSS to VCC
∝A VOUT = VSS to VCC
V
VCC + 0.5 V
0.4
V IOL = 3mA, VCC = 4.5V
6551 FRM T06.1
Symbol
CI/O (3)
CIN (3)
Parameter
Input/Output Capacitance (SDA)
Input Capacitance (S1, S2, SCL)
Max.
8
6
Units
pF
pF
Test Conditions
VI/O = 0V
VIN = 0V
Notes: (1)Must perform a stop command prior to measurement.
(2)VIL min. and VIH max. are for reference only and are not 100% tested. (3)This
parameter is periodically sampled and not 100% tested.
6551 FRM T07.1