English
Language : 

IC-HX_17 Datasheet, PDF (7/14 Pages) IC-Haus GmbH – 3-CHANNEL DIFFERENTIAL COLD LINE DRIVER
iC-HX
3-CHANNEL DIFFERENTIAL COLD LINE DRIVER
Rev D1, Page 7/14
OPERATING REQUIREMENTS
Operating Conditions:
VB1. . . 3 = 4.5. . . 40 V, VCC = 4.5. . . 5.5 V or VB1. . . 3 = VCC = 4. . . 5.5 V, Tj = -40. . . 140 °C, unless otherwise noted,
input level lo = 0...0.45 V, hi = 2.4 V...VCC, timing diagram see fig. 1
Item Symbol Parameter
No.
Conditions
Min.
Time Delays
I001 tplh(E-A) Propagation Delay Ex ⇒ Ax
DIFF = lo, Cl() = 100 pF
I002 tphl(E-A) Propagation Delay Ex ⇒ Ax
DIFF = lo, Cl() = 100 pF
I003 ∆tplh(Ax) Propagation Delay Skew
|A1 ⇒ A2|, |A3 ⇒ A4|, |A5 ⇒ A6|
DIFF = hi, Cl() = 100 pF
I004 ∆tphl(Ax) Propagation Delay Skew
|A1 ⇒ A2|, |A3 ⇒ A4|, |A5 ⇒ A6|
DIFF = hi, Cl() = 100 pF
I005 tplh(ENA) Propagation Delay ENA ⇒ Ax
Ex = hi, DIFF = lo, Cl() = 100 pF,
Rl(Ax, GND) = 5 kΩ
I006 tplh(ENA) Propagation Delay ENA ⇒ Ax
Ex = lo, DIFF = lo, Cl() = 100 pF,
Rl(VB, Ax) = 100 kΩ
I007 tphl(ENA) Propagation Delay ENA ⇒ Ax
Ex = lo, DIFF = lo, Rl(VB, Ax) = 5 kΩ
I008 tphl(ENA) Propagation Delay ENA ⇒ Ax
Ex = hi, DIFF = lo, Rl(Ax, GND) = 5 kΩ
I009 tphl(DIFF) Propagation Delay DIFF ⇒ A2, A4, A6 E1, E3, E5 = hi, Cl() = 100 pF
I010 tplh(DIFF) Propagation Delay DIFF ⇒ A2, A4, A6 E1, E3, E5 = lo, Cl() = 100 pF
I011 tplh(TNER) Propagation Delay TNER ⇒ NER
Rl(VB, NER) = 5 kΩ, Cl() = 100 pF
I012 tpoff(VBx) Turn-off delay, VBx ⇒ NER
| VBx - VBy | > Vth(VBx), x<>y, x, y = 1..3
0.3
Unit
Max.
400
ns
200
ns
100
ns
100
ns
300
ns
200
ns
500
ns
500
ns
250
ns
400
ns
2
µs
3
µs
V
2.4V
2.0V
Input/Output
0.8V
0.45V
t
1
0
Figure 1: Reference levels for delays