English
Language : 

IC-MFP Datasheet, PDF (6/13 Pages) IC-Haus GmbH – 8-FOLD FAIL-SAFE P-FET DRIVER
iC-MFP
8-FOLD FAIL-SAFE P-FET DRIVER
Rev A2, Page 6/13
ELECTRICAL CHARACTERISTICS
Operating Conditions: VB = VBR = 4.5. . . 40 V, GND = GNDR = 0 V, Tj = -40...125 °C unless otherwise stated
Item Symbol Parameter
No.
Conditions
Tj Fig.
Unit
°C
Min. Typ. Max.
Input IN1...8, EN5, EN10, ENFS
201 Vc()hi
Clamp Voltage hi
I() = 10 mA
42
60
V
202 Vc()lo
Clamp Voltage lo referenced to I() = -10 mA
the lower voltage of GND, GNDR
-2
-0.4
V
203 Vt()hi
Threshold Voltage hi
1.15
1.4
V
204 Vt()lo
Threshold Voltage lo
0.8
1.05
V
205 Vt()hys Input Hysteresis
Vt()hys = Vt()hi – Vt()lo
200
400 mV
206 Ipd1()
Pull-Down Current 1
0.4 V < V() < Vt()hi
5
75 225 350 µA
207 Ipd2()
Pull-Down Current 2
V() > 1.4 V
5
20
45
70
µA
208 Cin()
Input Capacitance
20
pF
209 Il()
Leakage Current
VB, VBR = 0 V, V() = 0..40 V
-10
10
µA
Supply and Temperature Monitor
301 VBon
Turn-On Threshold VB
3.8
4.3
V
302 VBoff
Turn-Off Threshold VB
Decreasing voltage VB
3.4
4.0
V
303 VBhys
Hysteresis
VBhys = VBon – VBoff
200
mV
304 Toff
Turn-Off Temperature
Increasing temperature
145 160 180 °C
305 Ton
Turn-On temperature
Decreasing temperature
130 147 170 °C
306 Thys
Hysteresis
Thys = Toff – Ton
13
°C
Ground Monitor GND, GNDR
401 Vt()hi
Threshold Voltage hi GND
Monitor
Referenced to GNDR
270 mV
402 Vt()lo
Threshold Voltage hi GND
Monitor
Referenced to GNDR
50
mV
403 Vt()hys Hysteresis
Vt()hys = Vt()hi – Vt()lo
5
100 mV
404 Vt()hi
Threshold Voltage hi GNDR
Monitor
Referenced to GND
270 mV
405 Vt()lo
Threshold Voltage lo GNDR
Monitor
Referenced to GND
50
mV
406 Vt()hys Hysteresis
Vt()hys = Vt()hi – Vt()lo
10
100 mV
407 Vc()hi
Clamp Voltage GNDR hi
referenced to GND
I() = 1 mA
0.4
2
V
408 Vc()lo
Clamp Voltage GNDR lo
referenced to GND
I() = -1 mA
-2
-0.4
V
Status Output NOK
501 Vc(NOK)hi Clamp Voltage hi
I() = 10 mA
42
60
V
502 Vc(NOK)lo Clamp Voltage lo referenced to I() = -10 mA
the lower voltage of GND, GNDR
-2
-0.4
V
503 Il(NOK) Leakage Current
GND < V(NOK) < VB
-20
20
µA
504 Vs(NOK)lo Saturation Voltage lo referenced I() = 0.5 mA
to GND
I() = 2 mA
0.2
V
0.8
V
505 Isc(NOK)lo Short circuit current lo
V() = 0.8 V...VB
2
3
10
mA
Supply Monitor VB, VBR
601 Vt(VB)hi Threshold Voltage hi VB Monitor Referenced to VBR
270 mV
602 Vt(VB)lo Threshold Voltage lo VB Monitor Referenced to VBR
50
mV
603 Vt(VB)hys Hysteresis
Vt()hys = Vt()hi – Vt()lo
5
100 mV
604 Vt(VBR)hi Threshold Voltage hi VBR
Monitor
Referenced to VB
270 mV
605 Vt(VBR)lo Threshold Voltage lo VBR
Referenced to VB
50
Monitor
606 Vt(VBR)hys Hysteresis
Vt()hys = Vt()hi – Vt()lo
5
100 mV
607 Vc(VBR)hi Clamp Voltage hi
I() = 1 mA, Vc() = V(VBR) - V(VB)
0.4
2
V
608 Vc(VBR)lo Clamp Voltage lo
I() = -1 mA, Vc() = V(VBR) -
V(VB)
-2
-0.4