English
Language : 

IC-TW14 Datasheet, PDF (5/33 Pages) IC-Haus GmbH – IC-PMX Companion Chip
iC-TW14
iC-PMX Companion Chip
Rev A1, Page 5/33
PIN FUNCTIONS
No. Name
1 MDI
2 MCL
3 VDD
4 GND
5 MRDY
6 NPRE
7 NCS
8 MISO
9 SH
10 VWP
11 HOP
12 HON
13 MOSI
14 SCK
15 TX
16 RX
17 P17
18 P18
19 P19
20 P20
21 RDY
22 P22
23 NRES
24 P24
I/O
Digital Output
Function
SSI Multi-turn Data output
Digital Input
SSI Multi-turn Clock
Supply
Supply common
Digital Output
Power Input
Power Supply and Signal
Common
SSI Multi-turn Data Ready
Digital Input, ac- Preset Multi-turn Position
tive low
Digital Output,
active low
Digital Input
Digital Output
Analog Input
SPI Chip Select
SPI Master Data Input
Switch Hall Sensor
Scaled Wiegand Pulse
Voltage
Analog Input
Analog Input
Digital Output
Digital Output
Digital Output
Digital Input
Digital Input
Digital Input,
active low
Hall Output Positive
Hall Output Negative
SPI Master Data Output
SPI Data Clock
UART Serial Output
UART Serial Input
Reserved
Reserved
Reserved
Reserved
iC-PMX Ready
Reserved
Reset Input
Reserved
Description
Connect to multiturn data input (MDI) pin of singleturn sensor and
pull-up resistor to VDD.
Connect to multiturn clock (MCL) pin of singleturn sensor and pull-up
resistor to VDD.
5V power input.
Connect to multiturn data ready (MRDY) pin of singleturn sensor and
pull-down resistor to GND.
Presets internal multiturn position to zero. Can be connected to a
push-button switch and pull-up resistor for easy calibration. Must be
pulled up to VDD if not used.
Connect to iC-PMX NCS (pin 26) and pull-up resistor to VDD.
Connect to iC-PMX MISO (pin 29) and pull-down resistor to GND.
Connect to iC-PMX SH (pin 25) and pull-down resistor to GND.
Connect to iC-PMX VWC via a resistive voltage divider to allow mea-
suring Wiegand pulse voltage without overloading the iC-TW14 ADC.
Connect to GND if Wiegand pulse voltage measurement diagnostic is
not required.
Connect to iC-PMX HOP (pin 23). Connect to GND if iC-PMX single-
turn sensors are not used.
Connect to iC-PMX HON (pin 24). Connect to GND if iC-PMX single-
turn sensors are not used.
Connect to iC-PMX MOSI (pin 28).
Connect to iC-PMX SCK (pin 27).
Serial output for communication with PC for setup and diagnostics.
Serial input for communication with PC for setup and diagnostics.
Connect to GND via pull-down resistor.
Connect to GND via pull-down resistor.
Connect to GND via pull-down resistor.
Connect to GND via pull-down resistor.
Connect to iC-PMX RDY (pin 30) and pull-down resistor to GND.
Connect to GND via pull-down resistor.
Must be connected to VDD through a pull-up resistor.
Connect to GND via pull-down resistor.