Rev C1, Page 5/10
ABSOLUTE MAXIMUM RATINGS
Beyond these values damage may occur; device operation is not guaranteed. Absolute Maximum Ratings are no Operating Conditions.
Integrated circuits with system interfaces, e.g. via cable accessible pins (I/O pins, line drivers) are per principle endangered by injected
interferences, which may compromise the function or durability. The robustness of the devices has to be verified by the user during system
development with regard to applying standards and ensured where necessary by additional protective circuitry. By the manufacturer
suggested protective circuitry is for information only and given without responsibility and has to be verified within the actual system with
respect to actual interferences.
Item Symbol
No.
G001 V()
G002 V(DN)
G003 I(DN)
G004 I(PI)
G005 I(NI)
G006 Vd()
G007 Tj
G008 Ts
G009 Eas
Parameter
Conditions
PI, NI Input Voltage with reference to
VN
DN Output Voltage
DN Output Current
PI Input Current
NI Input Current
ESD Susceptibility
Max. Junction Temperature
Storage Temperature Range
Inductive load switch-off energy
dissipation
V() = V(PI) − V(VN) or
V() = V(NI) − V(VN)
No free wheeling
HBM 100 pF discharged through 1.5 kΩ
Temperature monitor not active,
Tj < Ton
Min.
-0.3
-0.3
-10
-40
-40
Unit
Max.
40
V
40
V
300
mA
10
mA
mA
2
kV
150
°C
150
°C
5
mJ
THERMAL DATA
Operating Conditions: V(PI) = 4...36 V, unless otherwise stated
Item Symbol Parameter
No.
Conditions
T01 Ta
Ambient Temperature Range
Unit
Min. Typ. Max.
-40
120 °C
All voltages are referenced to ground (VN) unless otherwise stated.
All currents flowing into the device pins are positive; all currents flowing out of the device pins are negative.