English
Language : 

IC-LO Datasheet, PDF (18/21 Pages) IC-Haus GmbH – TRIANGULATION SENSOR
iC-LO
TRIANGULATION SENSOR
SPI INTERFACE
preliminary
Rev A1, Page 18/21
During SPI communication (NCS low) an ongoing
measurement sequence in iC-LO is halted (LED off,
switching output off).
The SPI protocol is equivalent to iC-Haus standard SPI
Interface A0.1. The following implemented commands
are described therein:
• REGISTER status/data
• REGISTER read (cont.)
• REGISTER write (cont.)
• STATUS read
• INSTRUCTION write
APPLICATION NOTES
The diagram shows a possible IO-Link compatible system with iC-GF acting as a switch and reverse polarity
protection for supply voltages of between 9 and 30 V.