English
Language : 

MB4U_17 Datasheet, PDF (12/16 Pages) IC-Haus GmbH – BiSS, SSI, PC-USB 2.0 ADAPTER
MB4U
BiSS, SSI, PC-USB 2.0 ADAPTER
preliminary
Rev C1, Page 12/16
Hex Editor Button and Selector Button Description
Area Select
Reads in sensor data
Read Register
Transfers configuration updates from the selected slave ID
Write Register
Transfers configuration updates to the selected slave ID
Save Reg. File
Saves sensor data to PC file
Load Reg. File
Loads sensor data from PC file
Fill
Fills all registers in the selected area with selected content or symbol
CRC Calculation
Calculates the CRC of a dedicated area
Figure 5: Register Access Screen (one tab each per slave ID)
Possible Errors
Main causes for errors:
• Using more than one software.
→ Please make sure that only one software is accessing the BiSS adapter at the same time.
• Insufficient power supply for all sensors attached.
→ The adapter will not respond if there is an overload due to the sensor(s) connected.
→ Please check wiring and use external power supply.
• Invalid transmission parameter settings.
→ Please check the sensor specific BiSS slave parameters, such as CRC polynomial etc.
→ Please check wiring and use external power supply.
• Invalid wiring
→ Please check wiring and use external power supply.