English
Language : 

MB4U_17 Datasheet, PDF (10/16 Pages) IC-Haus GmbH – BiSS, SSI, PC-USB 2.0 ADAPTER
MB4U
BiSS, SSI, PC-USB 2.0 ADAPTER
preliminary
Rev C1, Page 10/16
Configuration
To set the BiSS Master for the sensor(s) connected to it, select Config Slaves and manually configure the BiSS
parameters (data lengths, CRC polynomials, etc.) according to the sensor’s data sheet.
Auto Detection of the Connected Device Configuration
BiSS permits different possibilities and detail levels for an automatic detection of the connected device configura-
tion.
Implemented Auto Detection functions:
• Custom Auto Detection with selected XML file path
• Auto Detection via BiSS EDS
• Auto Detection via BiSS ID and standard BiSS XML file path
• Auto Detection via BiSS Profile ID
Figure 3: Automatic Detection
BiSS XML Files
The file "idbiss6943.xml" is a BiSS device description file for BiSS slave iCs of iC-Haus. Further XML files are
integrated with the date of the software release. For possible updates and new XML files please contact the
manufacturer of your sensor for an appropriate device description file or set the transmission parameters yourself
later. See also at the BiSS website in the identifier section for published XML files http://www.biss-interface.com .
BiSS Reader Configuration Files
Transmission parameter settings can be stored to a *.cfg file for later use with the BiSS software.
Those configuration files can be imported by API(DLL) functions.
Master Configuration Files
The "Save BiSS-Master-Config" writes an BiSS Master Chip configuration description into a *.txt file (e. g. setup of
MB100). Those BiSS master configuration files can be integrated into configuration code sets for programming
BiSS master iC´s or iP´s to a dedicated BiSS setup.