IC-RC1000_14 Datasheet, PDF (10/14 Pages) IC-Haus GmbH – SIN/COS SIGNAL SAFETY MONITOR IC
iC-RC1000
SIN/COS SIGNAL SAFETY MONITOR IC
Rev C2, Page 10/14
The following figure shows a SIN signal (PSIN-NSIN) and a COS signal (PCOS-NCOS) leading by just 45°, as
well as the Lissajous figure resulting from this phase shift. Additionally, the result of square sum generation is
also shown, here exceeding the monitoring thresholds for the maximum and minimum amplitudes.
1 Vpp
Square Sum Result
90°
φ
180°
0°
270°
Vpp()min
Vpp()max
0°
90°
180°
270°
360°
Figure 5: Monitoring of Lissajous figure regarding phase error tolerance
Input Circuits With Operational Amplifiers
For the detection of signal losses, caused by a fractured cable for instance, iC-RC1000 drags its input signals
into the DC check’s error range using integrated pull-down resistors. If operational amplifiers are connected
upstream, cable fracture detection now requires that the external circuit ensures an open external input causes
an invalid input signal at iC-RC1000 (violation of DC commen mode range).