IC-RC1000_14 Datasheet, PDF (10/14 Pages) IC-Haus GmbH – SIN/COS SIGNAL SAFETY MONITOR IC | |||
|
◁ |
iC-RC1000
SIN/COS SIGNAL SAFETY MONITOR IC
Rev C2, Page 10/14
The following ï¬gure shows a SIN signal (PSIN-NSIN) and a COS signal (PCOS-NCOS) leading by just 45°, as
well as the Lissajous ï¬gure resulting from this phase shift. Additionally, the result of square sum generation is
also shown, here exceeding the monitoring thresholds for the maximum and minimum amplitudes.
1 Vpp
Square Sum Result
90°
Ï
180°
0°
270°
Vpp()min
Vpp()max
0°
90°
180°
270°
360°
Figure 5: Monitoring of Lissajous ï¬gure regarding phase error tolerance
Input Circuits With Operational Ampliï¬ers
For the detection of signal losses, caused by a fractured cable for instance, iC-RC1000 drags its input signals
into the DC checkâs error range using integrated pull-down resistors. If operational ampliï¬ers are connected
upstream, cable fracture detection now requires that the external circuit ensures an open external input causes
an invalid input signal at iC-RC1000 (violation of DC commen mode range).
|
▷ |