HY29F800A Datasheet, PDF (9/40 Pages) Hynix Semiconductor – 8 Megabit (1Mx8/512Kx16), 5 Volt-only, Flash Memory
The flow chart in Figure 1 illustrates the proce-
dure for protecting sectors, and timing specifica-
tions and waveforms are shown in the specifica-
tions section of this document. Verification of pro-
tection is accomplished as described in the Elec-
tronic ID Mode section and shown in the flow chart.
The procedure for sector unprotection is illustrated
in the flow chart in Figure 2, and timing specifica-
tions and waveforms are given at the end of this
document. Note that to unprotect any sector, all
unprotected sectors must first be protected prior
to the first unprotect write cycle.
Sectors can also be temporarily unprotected as
described in the next section.
Temporary Sector Unprotect Operation
This feature allows temporary unprotection of pre-
viously protected sectors to allow changing the
data in-system. Temporary Sector Unprotect mode
is activated by setting the RESET# pin to VID. While
HY29F800A
in this mode, formerly protected sectors can be
programmed or erased by invoking the appropri-
ate commands (see Device Commands section).
Once VID is removed from RESET#, all the previ-
ously protected sectors are protected again. Fig-
ure 3 illustrates the algorithm.
Electronic ID Mode Operation
The Electronic ID mode provides manufacturer and
device identification and sector protection verifi-
cation through identifier codes output on DQ[7:0]
or DQ[15:0]. This mode is intended primarily for
programming equipment to automatically match a
device to be programmed with its corresponding
programming algorithm. The Electronic ID infor-
mation can also be obtained by the host through a
command sequence, as described in the Device
Commands section.
Operation in the Electronic ID mode requires VID
on address pin A[9], with additional requirements
START
NOTE: All sectors must be
previously protected.
APPLY V CC
Set: TRYCNT = 1
Set: NSEC = 0
Set: A9 = CE# = OE# = V ID
Set: RESET# = V IH
WE# = V IL
Wait tWPP2
WE# = V IH
Set:
A9 = V ID
OE# = CE# = V IL
Set Sector Group Address:
A[18:12] = Sector NSEC
A0 = A6 = V IL
A1 = V IH
Read Data
NO
Data = 0x00?
Increment TRYCNT
NO
YES
TRYCNT = 1000?
YES
YES
NSEC = 18?
NO
NSEC = NSEC + 1
Remove V ID from A9
SECTOR UNPROTECT
COMPLETE
DEVICE FAILURE
Figure 2. Sector Unprotect Procedure
Rev. 1.1/Feb 02
9