English
Language : 

HCPL-3100 Datasheet, PDF (9/10 Pages) Agilent(Hewlett-Packard) – Power MOSFET/IGBT Gate Drive Optocouplers
100
70°C
50°C
10
25°C
TA= 0°C
1
0.1
0.01
1.0 1.2 1.4 1.6 1.8 2.0 2.2
FORWARD VOLTAGE VF (V)
Figure 14. Typical Forward Current
vs. Forward Voltage, HCPL-3101.
1.2
1.6
TA = 25°C
VCC = 24 V
1.1
1.4
1.0
1.2
HCPL-3100
0.9
1.0
0.8
0.8
HCPL-3101
0.7
15
18
21
24
27
30
SUPPLY VOLTAGE VCC (V)
Figure 15. Normalized Low to High
Threshold Input Current vs. Supply
Voltage.
0.6
-25
0
25
50
75
100
AMBIENT TEMPERATURE TA (°C)
Figure 16. Normalized Low to High
Threshold Input Current vs. Ambient
Temperature.
0.4
0.2
0.1
0.05
0.02
0.01
0.005
0.01 0.02
VCC1 = 12 V
VCC2 = -12 V
TA = 25°C
IF = 5 mA, HCPL-3101
IF = 10 mA, HCPL 3100
0.05 0.1 0.2
0.5 1.0
OUTPUT 1 CURRENT I 01 (A)
0.5
VCC1 = 12 V
VCC2 = -12 V
0.4
IF = 5 mA, HCPL-3101
IF = 10 mA, HCPL 3100
0.3
0.2
I 01 = 0.1 A
0.1
0
-25
0
25
50
75
100
AMBIENT TEMPERATURE
30
TA= 25°C
I F = 5 mA, HCPL-3101
27
I F = 10 mA, HCPL-3100
24
21
18
15
12
15 18 21
24 27 30
33
SUPPLY VOLTAGE VCC(V)
Figure 17. Typical Low Level Output 1
Voltage vs. Output 1 Current.
Figure 18. Typical Low Level Output 1
Voltage vs. Ambient Temperature.
Figure 19. Typical High Level Output 2
Voltage vs. Supply Voltage.
24
23
I O2 = 0 A
22
21
IO2 = -0.1 A
20
19
18
-25
VCC = 24 V
I F = 5 mA, HCPL-3101
I F = 10 mA, HCPL-3100
0
25
50
75
100
AMBIENT TEMPERATURE TA (°C)
4
VCC = 6 V
2 TA = 25°C
IF = 0 mA
1
0.5
0.2
0.1
0.05
0.01 0.02 0.05 0.1 0.2
0.5 1.0
OUTPUT 2 CURRENT I O2 (A)
1.5
VCC = 24 V
IF = 0 mA
1.4
1.3
1.2
I 02 = 0.1 A
1.1
1.0
-25
0
25
50
75
100
AMBIENT TEMPERATURE TA (°C)
Figure 20. Typical High Level Output 2
Voltage vs. Ambient Temperature.
Figure 21. Typical Low Level Output 2
Voltage vs. Output 2 Current.
Figure 22. Typical Low Level Output 2
Voltage vs. Ambient Temperature.