Switching Specifications (TA = 25°C)
Parameter
Sym.
Device Min. Typ. Max. Units
Test Conditions
Fig. Note
Propagation
tPLH
Delay Time to
High Output
Level
Propagation
tPHL
Delay Time to
Low Output
Level
HCPL-3100 -
HCPL-3101 -
HCPL-3100 -
HCPL-3101 -
1
2
µs IF = 10 mA VCC = 24 V,
9, 2, 6
VO1 = 24 V,
25,
0.3 0.5 µs IF = 5 mA RG = 47 Ω,
26,
CG = 3000 pF 27
1
2
µs IF = 10 mA
0.3 0.5 µs IF = 5 mA
Rise Time
tr
HCPL-3100 -
0.2 0.5 µs IF = 10 mA
HCPL-3101
IF = 5 mA
Fall Time
tf
HCPL-3100 -
0.2 0.5 µs IF = 10 mA
HCPL-3101
IF = 5 mA
Output High
|CMH| HCPL-3100 1500 5000
- V/µs IF = 10 mA VCM = 600 V 10
2
Level Common
(peak),
Mode Transient
HCPL-3101
IF = 5mA VCC = 24 V
Immunity
VO1 = 24 V
∆V02H = ∆V02L
Output Low
|CML|
1500 5000 - V/µs IF = 0 mA
= 2.0 V
Level Common
Mode Transient
Immunity
Packaging Characteristics
Parameter
Input-Output Momentary
Withstand Voltage*
Resistance (Input-Output)
Capacitance (Input-Output)
Sym.
VISO
Min. Typ.
5000
Max. Units
V rms
RI-O
5x1010 1011
–
Ω
CI-O
–
1.2
–
pF
Test Conditions
Fig. Note
RH = 40% to 60%
4, 5
t = 1 min, TA = 25°C
VI-O = 500 V, TA = 25°C
4
RH = 40% to 60%
f = 1 MHz
4
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable), your
equipment level safety specification, or HP Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
Notes:
1. Derate absolute maximum ratings with ambient temperatures as shown in Figures 11 and 12.
2. A bypass capacitor of 0.01 µF or more is needed near the device between VCC and GND when measuring output and transfer
characteristics.
3. IFLH represents the forward current when the output goes from low to high.
4. Device considered a two terminal device; pins 1-4 are shorted together and pins 5-8 are shorted together.
5. For devices with minimum VISO specified at 5000 V rms, in accordance with UL 1577, each optocoupler is proof-tested by applying an
insulation test voltage ≥ 6000 V rms for one second (leakage current detection limit, II-O ≤ 200 µA).
6. The tPLH and tPHL propagation delays are measured from the 50% level of the input pulse to the 50% level of the output pulse.
7. R2 limits the Q1 and Q2 peak currents. For more applications and circuit design information see Application Note “Power Transistor
Gate/Base Drive Optocouplers.”
1-343