English
Language : 

HFCT-5903E Datasheet, PDF (7/12 Pages) Agilent(Hewlett-Packard) – MT-RJ Duplex Single Mode Transceiver
Performance Specifications
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause catastrophic damage to the device. Limits apply to each parameter
in isolation, all other parameters having values within the recommended operating conditions. It should not be assumed that
limiting values of more than one parameter can be applied to the product at the same time. Exposure to the absolute maximum
ratings for extended periods can adversely affect device reliability.
Parameter
Symbol Minimum Typical Maximum Units
Notes
Storage Temperature
Lead Soldering Temperature/Time
Output Current
Data Input Voltage
Power Supply Voltage
TS
-40
TSOLD /tSOLD
IO
0
VI
GND
VCC
0
+85
°C
+260/10 °C/s
30
mA
VCC
V
3.6
V
Operating Environment
Parameter
Ambient Operating Temperature
Power Supply Voltage
Data Input Voltage - Low
Data Input Voltage - High
Data and Signal Detect Output Load
Symbol
TA
VCC
VIL - VCC
VIH - VCC
RL
Minimum
0
3.1
-1.810
-1.165
Typical
50
Maximum
+70
3.5
-1.475
-0.880
Units
°C
V
V
V
W
Notes
1
2
Transmitter Section
(Ambient Operating Temperature VCC = 3.1 V to 3.5 V)
Parameter
Symbol Minimum Typical Maximum Units
Supply Current
Power Dissipation
Optical Output Power
Center Wavelength
Spectral Width
ICC
PDISS
PO
-20
lC
1261
Dl
50
120
0.175
0.42
-14
1360
7.7
mA
W
dBm avg.
nm
nm
Extinction Ratio
Output Optical Eye
ER
8.2
dB
Compliant with Eye Mask Bellcore TR-NWT-000253 and
ITU recommendation G.957
Optical Rise Time
tR
2
ns
Optical Fall Time
tF
2
ns
Data Input Current - Low
IIL
-200
µA
Data Input Current - High
IIH
200
µA
Data Input Voltage - Low
VIL - VCC -1.810
-1.475
V
Data Input Voltage - High
VIH - VCC -1.165
-0.880
V
Notes
3
4
5
5
6
6
Notes:
1. 2 ms-1 air flow required.
2. Outputs terminated with 50 W to VCC – 2V are the Thevenin equivalent.
3. The power supply current varies with temperature. Maximum current is specified at VCC = Maximum @ maximum temperature (not including
terminations) and end of life.
4. Output power is power coupled into a single mode fiber.
5. 10% - 90% Values
6. These inputs are compatible with 10 K, 10 KH, and 100 K ECL and LVPECL inputs.