English
Language : 

HFCT-5903E Datasheet, PDF (6/12 Pages) Agilent(Hewlett-Packard) – MT-RJ Duplex Single Mode Transceiver
Regulatory Compliance
Feature
Electrostatic Discharge
(ESD) to the Electrical Pins
Electrostatic Discharge
(ESD) to the Duplex MT-RJ
Receptacle
Test Method
MIL-STD-883C
Method 3015.4
Variation of IEC 801-2
Electromagnetic
Interference (EMI)
FCC Class B
CENELEC EN55022 Class B
(CISPR 22A)
VCCI Class 1
Immunity
Variation of IEC 801-3
Eye Safety
FDA CDRH 21-CFR 1040
Class 1
IEC 825 Issue 1 1993:11
Class 1
CENELEC EN60825 Class 1
Targeted Performance
Meets Class 1 (2000 Volts).
Products of this type, typically, withstand at least
25 kV without damage when the Duplex MT-RJ
Connector Receptacle is contacted by a Human
Body Model probe.
Transceivers typically provide 12 dB margin to the
noted standard limits when tested at a certified test
range with the transceiver mounted to a circuit card
without a chassis enclosure.
Three transceivers typically provide 20 dB of margin
in a ’perfect’ closed box with the recommended port
openings.
Typically show no measurable effect from a 10 V/m
field swept from 10 to 450 MHz applied to the
transceiver when mounted to a circuit card without a
chassis enclosure.
Compliant per Agilent testing under normal operating
conditions.
Accession Number: 9521220-20.
Compliant per Agilent testing under single fault
conditions.
TUV Certification: 933/510817/05.
6