English
Language : 

HCPL-261A Datasheet, PDF (7/16 Pages) Agilent(Hewlett-Packard) – HCMOS Compatible, High CMR, 10 MBd Optocouplers
Electrical Specifications
Over recommended operating temperature (TA = - 40°C to +85°C) unless otherwise specified.
Parameter
High Level Output
Current
Low Level Output
Voltage
High Level Supply
Current
Low Level Supply
Current
High Level Enable
Current**
Low Level Enable
Current**
Input Forward
Voltage
Temperature Co-
efficient of Forward
Voltage
Input Reverse
Breakdown Voltage
Input Capacitance
Symbol
IOH
VOL
ICCH
ICCL
IEH
IEL
VF
∆VF/∆TA
BVR
CIN
Min. Typ.*
3.1
0.4
7
9
8
12
-0.6
-0.9
1.0 1.3
-1.25
3
5
60
Max.
100
0.6
10
15
13
21
-1.6
Units
Test Conditions
µA VCC = 5.5 V, VO = 5.5 V,
VF = 0.8 V, VE = 2.0 V
V VCC = 5.5 V, IOL = 13 mA
(sinking), IF = 3.0 mA,
VE = 2.0 V
mA VE = 0.5 V**
Dual Channel
VCC = 5.5 V
IF = 0 mA
Products***
mA VE = 0.5 V**
Dual Channel
Products***
VCC = 5.5 V
IF = 3.0 mA
mA VCC = 5.5 V, VE = 2.0 V
Fig. Note
4 18
5, 8 4, 18
4
-1.6 mA VCC = 5.5 V, VE = 0.5 V
1.6
V IF = 4 mA
64
mV/°C IF = 4 mA
4
V IR = 100 µA
4
pF f = 1 MHz, VF = 0 V
*All typical values at TA = 25°C, VCC = 5 V
**Single Channel Products only (HCPL-261A/261N/061A/061N)
***Dual Channel Products only (HCPL-263A/263N/063A/063N)
1-172