English
Language : 

HCPL-261A Datasheet, PDF (10/16 Pages) Agilent(Hewlett-Packard) – HCMOS Compatible, High CMR, 10 MBd Optocouplers
15
80
VCC = 5.5 V
VCC = 5 V
VO = 5.5 V
VE = 2 V
VE = 2 V
VOL = 0.6 V
VF = 0.8 V
60
IF = 3.5 mA
10
40
5
20
0
-60 -40 -20 0 20 40 60 80 100
TA – TEMPERATURE – °C
Figure 4. Typical High Level Output
Current vs. Temperature.
5.0
4.0
3.0
2.0
RL = 4 kΩ
1.0
RL = 350 Ω
RL = 1 kΩ
0
0
0.5
1.0
1.5
2.0
IF – FORWARD INPUT CURRENT – mA
0
-60 -40 -20 0 20 40 60 80 100
TA – TEMPERATURE – °C
Figure 5. Low Level Output Current
vs. Temperature.
HCPL-261A fig 5
0.6
VCC = 5.5 V
VE = 2 V
0.5
IF = 3.0 mA
IO = 16 mA
IO = 12.8 mA
0.4
0.3
IO = 9.6 mA
IO = 6.4 mA
0.2
-60 -40 -20 0 20 40 60 80 100
TA – TEMPERATURE – °C
Figure 7. Typical Output Voltage vs.
Forward Input Current.
Figure 8. Typical Low Level Output
Voltage vs. Temperature.
100.0
10.0
TA = 85 °C
1.0
TA = 40 °C
TA = 25 °C
0.1
IF
+
0.01
V–F
1.0 1.1 1.2 1.3 1.4 1.5
VF – FORWARD VOLTAGE – V
Figure 6. Typical Diode Input
Forward Current Characteristic.
PULSE GEN.
IF
ZO= 50 Ω
tf = tr = 5 ns
INPUT
MONITORING
NODE
RM
HCPL-261A/261N
1
VCC 8
2
7
3
6
4
5
GND
+5 V
0.1 µF
BYPASS
*CL
RL
OUTPUT VO
MONITORING
NODE
*CL IS APPROXIMATELY 15 pF WHICH INCLUDES
PROBE AND STRAY WIRING CAPACITANCE.
INPUT
IF
OUTPUT
VO
t PHL
t PLH
IF = 3.5 mA
IF = 1.75 mA
1.5 V
Figure 9. Test Circuit for tPHL and tPLH.
10%
90%
trise
90%
VOH
10%
tfall
VOL
1-175