Feature
Header Selection
Trailer Selection
Reader Address
Selection
Message Ready/Not
Ready Response
Selection
No-Read Message
Selection
No-Read
Recognition
Enable
Single Read Mode 1
Enable
Single Read Mode 2
Enable
Output Buffering
Enable
Scanner Type
Selection
Laser Shutoff
Delay Selection
Laser Redundancy
Check Enable
Continuous Laser
Read Mode Enable
Function or Value
A string of characters pre-
pended to the decoded message
(10 characters, maximum)
A string of characters appended
to the decoded message
(10 characters, maximum)
Reader Address is transmitted at
the beginning of decoded and No-
Read messages for polling
purposes. (1 character)
The Message Ready/Not Ready re-
sponse is transmitted after the
reader receives a status request
type 3 and is used with Single
Read Mode 2. (1 character each)
The No-Read Message configured
is transmitted each time there
is an unsuccessful read
(10 characters, maximum)
Controls whether the decoder
detects unsuccessful reads
and sends the No-Read Message
Controls reading and automatic
transmission of decoded
messages
Controls separate reading of
bar codes and triggering decoded
message transmission
Characters to be transmitted
are entered into a 256 character
queue for use with a pacing
protocol
Determines whether a wand or
laser is to be used
Defines laser on time prior to
automatic shutoff, from 0 to 10
seconds in 100 ms steps
Enables requirement for two
consecutive, identical decodes
for a good read
When enabled, the laser is turned
on permanently instead of waiting
for the trigger to be pulled
Selection
Software
Software
Software
Software
Software
Software
Software
Software
Software
Hardwire
Software
Software
Software
Default Setting
none
CR LF
none
ACK/NAK
none
Disabled
Disabled
Disabled
Disabled
Depends on pin
SCT
3 seconds
Disabled
Disabled
(continued)