HCPL-7720 Datasheet, PDF (6/18 Pages) Agilent(Hewlett-Packard) – 40 ns Propagation Delay CMOS Optocoupler
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option 060)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤150 V rms
for rated mains voltage ≤300 V rms
for rated mains voltage ≤450 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b†
VIORM x 1.875 = VPR, 100% Production
Test with tm = 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a†
VIORM x 1.5 = VPR, Type and Sample Test,
tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage†
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, V10 = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
TS
IS,INPUT
PS,OUTPUT
RIO
HCPL-772X
Option 060
I-IV
I-IV
I-III
55/85/21
2
630
1181
945
6000
175
230
600
≥109
HCPL-072X
Option 060
I-IV
I-III
55/85/21
2
560
1050
Units
V peak
V peak
840
V peak
4000
V peak
150
°C
150
mA
600
mW
≥109
Ω
† Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section
IEC/EN/DIN EN 60747-5-2, for a detailed description.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured
by means of protective circuits.
Note: The surface mount classification is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
Parameter
Storage Temperature
Ambient Operating Temperature[1]
Supply Voltages
Input Voltage
Output Voltage
Average Output Current
Lead Solder Temperature
Solder Reflow Temperature Profile
Symbol
TS
TA
VDD1, VDD2
VI
VO
IO
Min.
Max.
Units
–55
125
°C
–40
+85
°C
0
6.0
Volts
–0.5
VDD1 +0.5
Volts
–0.5
VDD2 +0.5
Volts
10
mA
260°C for 10 sec., 1.6 mm below seating plane
See Solder Reflow Temperature Profile Section
Figure
Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Supply Voltages
Logic High Input Voltage
Logic Low Input Voltage
Input Signal Rise and Fall Times
6
Symbol
TA
VDD1, VDD2
VIH
VIL
tr, tf
Min.
–40
4.5
2.0
0.0
Max.
+85
5.5
VDD1
0.8
1.0
Units
°C
V
V
V
ms
Figure
1, 2