English
Language : 

HCPL270L Datasheet, PDF (5/12 Pages) Agilent(Hewlett-Packard) – Low Input Current High Gain LVTTL/LVCMOS Compatible 3.3 V Optocouplers
Insulation and Safety Related Specifications
Parameter
Minimum External Air
Gap (External Clearance)
Minimum External Tracking
(External Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Symbol
L (101)
L (102)
8-Pin DIP
(300 Mil)
Value
7.1
7.4
0.08
Minimum Internal Tracking
NA
(Internal Creepage)
Tracking Resistance
CTI
200
(Comparative Tracking
Index)
Isolation Group
IIIa
SO-8
Value
4.9
4.8
0.08
NA
200
IIIa
Units
mm
mm
mm
mm
Volts
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance, conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity.
Measured from input terminals to output
terminals, along internal cavity.
DIN IEC 112/VDE 0303 Part 1.
Material Group (DIN VDE 0110, 1/89, Table 1).
VDE 0884 Insulation Related Characteristics
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 450 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VPR = 1.875 x VIORM, 100% Production Test with tP = 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
VPR = 1.5 x VIORM, Type and Sample Test,
tP = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 11, Thermal Derating curve.)
Case Temperature
Current (Input Current IF, PS = 0)
Output Power
Insulation Resistance at TS, VIO = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
TS
IS,INPUT
PS,OUTPUT
RS
Characteristic Units
I-IV
I-III
55/100/21
2
630
Vpeak
1181
Vpeak
945
6000
Vpeak
Vpeak
175
˚C
400
mA
600
mW
≥ 109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, (VDE 0884), for a detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
5