English
Language : 

HCPL-3000 Datasheet, PDF (5/9 Pages) Agilent(Hewlett-Packard) – Power Bipolar Transistor Base Drive Optocoupler
Switching Specifications (TA = 25°C)
Parameter
Sym. Min. Typ. Max. Units
Test Conditions
Fig. Note
Propagation Delay
Time to High Output
Level
tPLH
-
2
5
µs VCC = 6 V, IF = 5 mA,
7, 2, 6
RL1 = 5 Ω, RL2 = 10 Ω
24,
25
Propagation Delay Time tPHL -
2
5
to Low Output Level
Rise Time
tr
- 0.2 1
Fall Time
tf
- 0.1 1
Output High Level
Common Mode
Transient Immunity
|CMH| 1500 -
-
V/µs VCM = 600 V Peak,
8
2
IF = 5mA, RL1 = 470 Ω,
RL2 = 1 kΩ, ∆V02H = 0.5 V
Output Low Level
Common Mode
Transient Immunity
|CML| 1500 -
-
V/µs VCM = 600 V Peak,
IF = 0 mA, RL1 = 470 Ω,
RL2 = 1 kΩ, ∆V02L = 0.5 V
Package Characteristics
Parameter
Sym. Min. Typ. Max. Units
Test Conditions
Fig. Note
Input-Output Momentary VISO 5000
Withstand Voltage*
V rms RH = 40% to 60%,
4, 5
t = 1 min., TA = 25°C
Resistance
RI-O 5x1010 1011
–
Ω
VI-O = 500 V, TA = 25°C,
4
(Input-Output)
RH = 40% to 60%
Capacitance
CI-O
–
1.2
–
pF f = 1 MHz
4
(Input-Output)
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable), your
equipment level safety specification, or HP Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
Notes:
1. Derate absolute maximum ratings with ambient temperatures as shown in Figures 9, 10, and 11.
2. A bypass capacitor of 0.01 µF or more is needed near the device between VCC and GND when measuring output and transfer
characteristics.
3. IFLH represents the forward current when the output goes from low to high.
4. Device considered a two terminal device; pins 1-4 are shorted together and pin 5-8 are shorted together.
5. For devices with minimum VISO specified at 5000 V rms, in accordance with UL1577, each optocoupler is proof-tested by applying an
insulation test voltage ≥ 6000 V rms for one second (leakage current detection limit, II-O ≤ 200 µA).
6. The tPLH and tPHL propagation delays are measured from the 50% level of the input pulse to the 50% level of the output pulse.
7. R1 sets the base current (IO1 in Figure 1) supplied to the power bipolar device. R2 limits the peak current seen by Q2 when the device
is turning off. For more applications and circuit design information see Application Note “Power Transistor Gate/Base Drive
Optocouplers.”
1-333