English
Language : 

U1230 Datasheet, PDF (3/10 Pages) Agilent(Hewlett-Packard) – Handheld Digital Multimeter (DMM)
Electrical Specifications
DC specifications
Accuracy ±
(% of reading + counts Test
of least significant digit) current
Burden
voltage/
shunt
Input
impedance
Function
Voltage
Resistance
Diode3
Current
Range
600 mV1
6V
60 V
600 V
600 V
(VZLOW)2
600 Ω4
6 kΩ4
60 kΩ
600 kΩ
6 MΩ5
60 MΩ5
2V
60 μA1
600 μA1
6 A2
10 A2, 3
U1231A/U1232A/
Resolution U1233A
0.1 mV
0.001 V
0.01 V
0.1 V
0.1 V
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
2% + 3
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.001 V
0.01 μA
0.1 μA
0.001 A
0.01 A
0.9% + 3
0.9% + 3
0.9% + 3
0.9% + 3
0.9% + 3
1.5% + 3
0.9% + 2
1.0% + 24
1.0% + 24
1.0% + 34
1.0% + 34
Where
Where
Where
(applicable) (applicable) (applicable)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
11.18 MΩ
11.18 MΩ
10.1 MΩ
10 MΩ
3 kΩ
0.57 mA
NA
NA
57 μA
NA
NA
5.7 μA
NA
NA
570 nA
NA
NA
100 nA/10 MΩ NA
NA
100 nA/10 MΩ NA
NA
0.57 mA
NA
NA
NA
< 2.5 V/1 kΩ NA
NA
< 2.5 V/1 kΩ NA
NA
< 0.2 V/0.005 Ω NA
NA
< 0.4 V/0.005 Ω NA
Notes for DC voltage specifications:
1. The accuracy of the 600 mV range is specified after the Null function is used to subtract the thermal effect (by shorting the test leads).
2. For VZLOW (low input impedance) measurements, auto-ranging is disabled and the multimeter’s range is set to 600 V in the manual ranging mode.
Notes for resistance specifications:
1. Overload protection: 600 Vrms for short circuits with < 0.3 A current.
2. Maximum open voltage is < +3 V.
3. Built-in buzzer beeps when the resistance measured is less than 23 Ω ± 10 Ω. The multimeter can capture intermittent measurements longer than 1 ms.
4. The accuracy of the 600 Ω to 6 kΩ range is specified after the Null function is used to subtract the test lead resistance and thermal effect (by shorting
the test leads).
5. For the ranges of 6 MΩ and 60 MΩ, the RH is specified for < 60%.
Notes for diode specifications:
1. Overload protection: 600 Vrms for short circuits with < 0.3 A current.
2. Built-in buzzer beeps continuously when the voltage measured is less than 50 mV and beeps once for forward-biased diode or semiconductor
junctions measured between 0.3 V and 0.8 V (0.3 V ≤ reading ≤ 0.8 V).
3. Open voltage for diode: < +3 V DC.
4. The maximum display for diode measurements is 2100 counts.
Notes for DC current specifications:
1. Overload protection for 60 μA to 600 μA range: 600 Vrms for short circuits with < 0.3 A current.
2. Overload protection for 6 A to 10 A range: 11 A/1000 V; 10 × 38 mm fast-acting fuse.
3. Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 A to 20 A for 30 seconds maximum. After
measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low current measurements.
4. Only applicable for the U1232/U1233 Series
3