English
Language : 

N2640A Datasheet, PDF (3/8 Pages) Agilent(Hewlett-Packard) – Technical Data, Software Release 3.0
N2644A Series Category 6A Universal Channel and Permanent Link SmartProbes,
Class F [2] Channel and Permanent Link SmartProbes
Universal Channel and Permanent Link
SmartProbes enable the WireScope
Pro to certify LAN cables, permanent
links and channel adapters. Once
inserted in the module bay of the
WireScope Pro, both, SmartProbes and
instrument, are automatically set up
and ready to perform standards-based
cable certification tests.
General Specifications
Size: 79.5 mm x 60.5 mm x 44 mm
(3.1” x 2.4” x 1.7”), excludes cable
Operating Temperature
0°C to +40°C
Storage Temperature
–40°C to +55°C
Measurement Parameter
Length
Propagation Delay and Skew
Attenuation
Near End Crosstalk (NEXT)
Equal Level Far End Crosstalk
(ELFEXT)
Resistance [3]
Network Specifications
Cabling Standards
Ethernet
Legacy Networks
Supported Tests
Range
0 – 180 m at NVP > 0.6
0 – 330 m at NVP > 0.6, single ended
0 – 1100 ns
60 dB
90 dB
90 dB
5 – 1000 Ohm
Resolution
0.5 m at NVP = 0.7
±1 ns
0.1 dB
0.1 dB
0.1 dB
1 Ohm
Accuracy
±1m
± 6 ns
[1]
[1]
[1]
±5%
TIA/EIA-606-A and TIA/EIA-568-B Category 3 through 6A
ISO/IEC 11801, EN 50173 and Australia/New Zealand Classes C, D, E, E and F
A
UTP, STP and SCTP cabling
IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T, 10GBASE-T
IEEE 802.5 Token Ring and IBM Type 1
TP PMD interfaces
Attenuation (Insertion Loss)
Near End Crosstalk (NEXT) in pair-to-pair and/or PowerSum format
Equal Level Far End Crosstalk (ELFEXT)
Return Loss
Loop Resistance [3]
Wiremap [3]
Cable length (dual-ended and single ended test)
Total Propagation Delay and Delay Skew between pairs
[1] If not mentioned otherwise, specifications are according to ISO Level IV definition.
[2] The term “Category 7” has been widely used as a synonym of ISO/IEC Class F, yet it is not a TIA/EIA standardized term. Product labels and
documentation may contain either term. Future documents and labels will use the term “Class F”.
[3] Available only for DC coupled structured cabling.
Page 3 of 8