English
Language : 

HPMX-7102 Datasheet, PDF (3/16 Pages) Agilent(Hewlett-Packard) – Dual-Band, Tri-Mode Downconverter
HPMX-7102 Summary Characterization Information
Standard test conditions apply unless otherwise noted.
Symbol
Parameters and Test Conditions
Min.
Typ.
Max.
PCS CDMA
Gc
NF
IIP3
OIP3
RL
RL
RL
Icc
Cellular CDMA
Gc
NF
IIP3
OIP3
RL
RL
RL
Icc
Cellular AMPS
Gc
NF
IIP3
OIP3
RL
RL
RL
Icc
Conversion Gain
Noise Figure
Input Third Order Intercept
Output Third Order Intercept
RF port Return Loss*
IF port Return Loss*
LO port Return Loss*
Current
Vcs = 3 V
Vcs = 1.5 V
Vcs = 3 V
Vcs = 1.5 V
Vcs = 3 V
Vcs = 1.5 V
Vcs = 3 V
Vcs = 1.5 V
Vcs = 3V
Vcs = 1.5V
Conversion Gain
Vcs = 2.5 V
Vcs = 1.5 V
Noise Figure
Vcs = 2.5 V
Vcs = 1.5 V
Input Third Order Intercept
Vcs = 2.5 V
Vcs = 1.5 V
Output Third Order Intercept Vcs = 2.5 V
Vcs = 1.5 V
RF port Return Loss*
IF port Return Loss*
LO port Return Loss*
Current
Vcs = 3V
Vcs = 1.5V
Conversion Gain
Vcs = 3 V
Vcs = 1.5 V
Noise Figure
Vcs = 3 V
Vcs = 1.5 V
Input Third Order Intercept
Vcs = 3 V
Vcs = 1.5 V
Output Third Order Intercept Vcs = 3 V
Vcs = 1.5 V
RF port Return Loss*
IF port Return Loss*
LO port Return Loss*
Current
Vcs = 3V
Vcs = 1.5V
11
12
11
10
11.5
8
2
5
0
17
11
-13
-15
-11
18
22
9
16
17
16
9
10
6
2
6
1
23
18
-14
-10
-11
16
20
10
15
16
15
7
8.5
6
0
2
-4
18
11
-11
-11
-11
10
13
6
* Externally matched
* For both LO and RF port return loss measurements, calibration removes all filters and attenuator pads shown in Figure 46.
* For IF port return loss measurements, the transformer is included in reported performance.
Units
dB
dB
dBm
dBm
dB
dB
dB
mA
mA
dB
dB
dB
dB
dBm
dBm
dBm
dBm
dB
dB
dB
mA
mA
dB
dB
dB
dB
dBm
dBm
dBm
dBm
dB
dB
dB
mA
mA
3