English
Language : 

HPMX-7102 Datasheet, PDF (2/16 Pages) Agilent(Hewlett-Packard) – Dual-Band, Tri-Mode Downconverter
HPMX-7102 Absolute Maximum Ratings[1]
Parameter
Units
Min.
Vcc Supply Voltage
Vcs Control Voltage
Vmode, Vband
Mixer Input, RF Power
Mixer Input, LO Power
Case Temperature
Storage Temperature
V
V
V
dBm
dBm
°C
°C
-55
Recommended operating range of Vcc = 2.7 to 3.6V, Ta = -40 to +85°C.
Max.
5
Vcc + 0.5
Vcc
5
7
125
125
Note:
1. Operation of this device in excess of any of
these limits may cause permanent damage.
HPMX-7102 Standard Test Conditions
Unless otherwise stated, all test data was taken on packaged parts under the following conditions:
Vcc = +3.0VDC, Tambient = 25°C, Icc at Vcs = 3V for CDMA 1900 and AMPS and Vcs = 2.5V for CDMA 800
ZRF & LO source = 50Ω, ZIF load = 500Ω. See Figure 46 for reference.
PCS CDMA:
LO input: 1749.62 MHz, -3 dBm, single-ended
RF input: 1960 MHz, -33 dBm, single-ended
IF output: 210.38 MHz
Cellular CDMA:
LO input: 966.88 MHz, -6 dBm, single-ended
RF input: 881 MHz, -33 dBm, single-ended
IF output: 85.38 MHz
Cellular AMPS:
LO input: 966.88 MHz, -6 dBm, single-ended
RF input: 881 MHz, -33 dBm, single-ended
IF output: 85.38 MHz