English
Language : 

DRR1-38XX Datasheet, PDF (3/4 Pages) Agilent(Hewlett-Packard) – Digital Radio Receiver Down Converter Modules for 37 to 40GHz
DRR1-38XX Typical Performance
28
Spec Max
26
24
22
T = +25°C
20 T = –30°C
T = +70°C
18
Spec Min
16
36.5
37.5
38.5
39.5
40.5
FREQUENCY (GHz)
22
T = +25°C
20 T = –30°C
T = +70°C
18
16
14
12
10
Spec Min
8
36.5
37.5
38.5
39.5
40.5
FREQUENCY (GHz)
Figure 1. Conversion Gain vs.
Frequency.
Figure 2. Image Rejection vs.
Frequency.
9
Spec Max
8
7
T = +25°C
T = –30°C
6
T = +70°C
5
36.5
37.5
38.5
39.5
40.5
FREQUENCY (GHz)
Figure 3. Noise Figure vs. Frequency.
-5
T = +25°C
T = –30°C
T = +70°C
-10
-15
-20
Spec Min
-25
36.5
37.5
38.5
39.5
40.5
FREQUENCY (GHz)
Figure 4. Power In at P1dB Out vs.
Frequency.
-20
-40
-60
-80
-100
-120
1
10
100
KHz Offset from Carrier
1000
Figure 5. Phase Noise at 40 GHz vs.
KHz Offset from Carrier.
41
600
40
500
TUNING VOLTAGE
39
400
38
MODULATION
SENSITIVITY
300
37
36
200
2
4
6
8 10 12 14
TUNING VOLTAGE (V)
Figure 6. Tuning Voltage vs. Frequency
and Modulation Sensitivity.
Powering Up Instructions
The -5 volts must be applied to the
receiver module before applying
the +5 volts. Likewise when
shutting down the receiver
module the +5␣ volts must be
removed before the -5 volts is
turned off. The +8.5␣ volts can be
turned on in any sequence. Failure
to follow this procedure could
cause permanent damage to the
module.
Mounting Instructions
Case must be mounted firmly,
with screws, to an adequate
metallic structure that has suffi-
cient thermal properties to
maintain the module case at a
temperature not to exceed 70°C.
Product Options
Specify part number followed by option. For example:
DR R 1 – 38 X X
Model Number Prefix = Digital Radio
R = Receiver Module
Internal Use
8-10
3 = WR-28 Waveguide Connector
1 = 630 MHz IF Frequency
2 = 1260 MHz IF Frequency
38 = 37 to 40 GHz Frequency Band