English
Language : 

DRR1-38XX Datasheet, PDF (2/4 Pages) Agilent(Hewlett-Packard) – Digital Radio Receiver Down Converter Modules for 37 to 40GHz
DRR1-38XX Absolute Maximum Ratings (T = -30 to +70ºC)
A
Parameters
Units
Ratings
DC Circuit Power +8.5
+5.0
-5.0
Tuning Voltage
Volts
10
Volts
+5.5
Volts
-5.5
Volts
14
Notes:
1. Operation in excess of any one of these parameters may result in permanent
damage.
2. A thermal interface medium must be used between the bottom of the
package and its mating surface to ensure optimum heat transfer.
DRR1-38XX Electrical Characteristics
Parameters
Units
Min.
Typ.
Max.
Extended
Range
39.5 – 40.0
RF Tuning Range
GHz
37
39.5
40
IF Frequency
MHz
630 or 1260
IF Bandwidth
MHz ± 20
LO Frequency
GHz
RF – IF
Gain[1]
dB
18
27 16 Min
Gain Flatness over 300 MHz
dB
±1
± 1.5
Noise Figure
dB
7.5
9 9.5 Max
Operating Temperature Range
°C
-30
70
Power Input at P-1dB
dBm -20 -17
LO Leakage at I[2]
dBm
-15
LO Leakage at R[3]
dBm
-15
Return Loss RF Port[4]
dB
8
10
5 Min
Return Loss IF Port
dB
14
Image Rejection
dB
10
13
Sample Out Frequency
MHz 1,010
1,080 1,094
Sample Out Power
dBm -10
0
Spurious Output[5]
dBc
-60
Phase Noise @ 100 KHz
dBc/Hz
-83 -80
Tuning Voltage
V
1
12 15 Max
Input Capacitance, Nom
pf
1,000
LO Tuning Sensitivity
MHz/V
400 500
LO Tuning Sensitivity Variation
1.5 : 1
DC Circuit Power: 8.5 Volts
mA
270 350
5 Volts
mA
470 650
-5 Volts
mA
20 30
Case Dimensions
inches
3.5 x 1.25 x 0.40
Max Power at Input/no damage
dBm
7
Humidity
Non Condensing %
85
Condensing
%
95
Connectors
WR 28
Notes:
1. Gain degrades to 16␣ dB minimum from 39.5 to 40␣ GHz.
2. LO and Harmonic/sub-harmonic leakage at I with RF terminated into a waveguide.
3. LO and Harmonic/sub-harmonic leakage at R up to 50 GHz.
4. RF port return loss degrades to 5␣ dB minimum from 39.5 to 40␣ GHz.
5. Measured at IF port within the IF bandwidth with single tone RF input of < - 20 dBm.
8-9