English
Language : 

35670A Datasheet, PDF (3/10 Pages) Agilent(Hewlett-Packard) – Dynamic Signal Analyzer
Source outputs
Random
Burst random
Periodic chirp
Burst chirp
Pink noise
Fixed sine
Note: Some source types are not available for use in
optional modes. See option description for details.
Input channels
Manual range
Anti-alias filters On/Off
Up-only auto range
AC or DC coupling
Up/down auto range
LED half range and overload
indicators
Floating or grounded
A-weight filters On/Off
Transducer power supplies (4 ma constant current)
Frequency
20 spans from 195 mHz to 102.4 kHz (1 channel mode)
20 spans from 98 mHz to 51.2 kHz (2 channel mode)
Digital zoom with 244 µHz resolution throughout the
102.4 kHz frequency bands.
Resolution
100, 200, 400, 800 and 1600 lines
Windows
Hann
Flat top
Uniform
Force/exponential
Math
+,-,*, /
Magnitude
Square Root
LN
*jω or /jω
Differentiation
Integration
Conjugate
Real and imaginary
FFT, FFT-1
EXP
PSD
A, B, and C weighting
Constants K1 thru K5
Functions F1 thru F5
Analysis
Limit test with pass/fail
Data table with tabular readout
Data editing
Time capture functions
Capture transient events for repeated analysis in FFT,
octave, order, histogram, or correlation modes (except
swept-sine). Time-captured data may be saved to internal
or external disk, or transferred over GPIB. Zoom on
captured data for detailed narrowband analysis.
Data storage functions
Built-in 3.5 in., 1.44-Mbyte flexible disk also supports
720-KByte disks, and 2 Mbyte NVRAM disk. Both
MS-DOS® and HP-LIF formats are available. Data can be
formatted as either ASCII or binary (SDF). The 35670A
provides storage and recall from the internal disk, internal
RAM disk, internal NVRAM disk, or external GPIB disk for
any of the following information:
Instrument setup states
User-math
Time capture buffers
Waterfall display data
Data tables
Trace data
Limit data
Agilent Instrument BASIC
Programs
Curve fit/synthesis tables
GPIB capabilities
Conforms to IEEE 488.1/488.2
Conforms to SCPI 1992
Controller with Agilent Instrument Basic Option
Calibration & memory
Single or automatic calibration
Built-in diagnostics & service tests
Nonvolatile clock with time/date
Time/date stamp on plots and saved data files
Online help
Access to topics via keyboard or index
Fan
On/Off
3