S-parameter test set interface
Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-SUB (25-pin)
Caution
Do not connect a printer to this connector. If you connect a printer with the S-parameter
test set interface connector (TEST SET-I/0 INTERCONNECT), it may cause damage to
the printer.
Figure 1-11. S-parameter test set interface pin assignments
External monitor output
Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-SUB (15-pin HD)
Display resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 640 x 480 VGA
Operation conditions
Temperature
Disk drive non-operating condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 °C to 40 °C
Disk drive operating condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 °C to 40 °C
Humidity
at wet bulb temperature ≤ 29 °C, without condensation
Disk drive non-operating condition . . . . . . . . . . . . . . . . . . . . . . . . . . 15% to 95% RH
Disk drive operating condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15% to 80% RH
Altitude. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 2,000 m
Warm up time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 minutes
Non-operation conditions
Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20 °C to 60 °C
Humidity
at wet bulb temperature ≤ 45 °C, without condensation. . . . . . . . . . . 15% to 95% RH
Altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 4,572 m
Others
EMC . . . . . . . . . . .Complies with CISPR 11 (1990) / EN 55011(1991) : Group 1, Class A
Complies with EN 50082-1 (1992) / IEC 1000-4-2 (1995) : 4 kV CD, 8 kV AD
Complies with EN 50082-1 (1992) / IEC 801-3 (1984) : 3 V/m
Complies with EN 50082-1 (1992) / IEC 1000-4-4 (1995) :1 kV / Main, 0.5kV /Signal line
Complies with IEC 1000-3-2 (1995) / EN 61000-3-2 (1995)
Complies with IEC 1000-3-3 (1994) / EN 61000-3-3 (1995)
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Complies with IEC 1010-1 (1990),
Amendment 1(1992), Amendment 2 (1995)
Certified by CSA-C22.2 No.1010.1-92
Power requirements . . . . . . 90 V to 132 V, or 198 V to 264 V (automatically switched),
47 to 63 Hz, 300 VA max.
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 kg (SPC)
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425 (W) x 235 (H) x 553 (D) mm
19