English
Language : 

HCNR200 Datasheet, PDF (1/16 Pages) Agilent(Hewlett-Packard) – High-Linearity Analog Optocouplers
H
High-Linearity Analog
Optocouplers
Technical Data
HCNR200
HCNR201
Features
• Low Nonlinearity: 0.01%
• K3 (IPD2/IPD1) Transfer Gain
HCNR200: ± 15%
HCNR201: ± 5%
• Low Gain Temperature
Coefficient: -65 ppm/°C
• Wide Bandwidth – DC to
>1 MHz
• Worldwide Safety Approval
- UL 1577 Recognized
(5 kV rms/1 min Rating)
- CSA Approved
- BSI Certified
- VDE 0884 Approved
VIORM = 1414 V peak
(Option #050)
• Surface Mount Option
Available
(Option #300)
• 8-Pin DIP Package - 0.400"
Spacing
• Allows Flexible Circuit
Design
• Special Selection for
HCNR201: Tighter K1, K3
and Lower Nonlinearity
Available
Applications
• Low Cost Analog Isolation
• Telecom: Modem, PBX
• Industrial Process Control:
Transducer Isolator
Isolator for Thermocouples
4 mA to 20 mA Loop Isolation
• SMPS Feedback Loop, SMPS
Feedforward
• Monitor Motor Supply
Voltage
• Medical
Description
The HCNR200/201 high-linearity
analog optocoupler consists of a
high-performance AlGaAs LED
that illuminates two closely
matched photodiodes. The input
photodiode can be used to
monitor, and therefore stabilize,
the light output of the LED. As a
result, the nonlinearity and drift
Schematic
1
LED CATHODE
–
VF
+
IF
LED ANODE
2
characteristics of the LED can be
virtually eliminated. The output
photodiode produces a photocur-
rent that is linearly related to the
light output of the LED. The close
matching of the photodiodes and
advanced design of the package
ensure the high linearity and
stable gain characteristics of the
optocoupler.
The HCNR200/201 can be used to
isolate analog signals in a wide
variety of applications that
require good stability, linearity,
bandwidth and low cost. The
HCNR200/201 is very flexible
and, by appropriate design of the
application circuit, is capable of
operating in many different
modes, including: unipolar/
bipolar, ac/dc and inverting/non-
inverting. The HCNR200/201 is
an excellent solution for many
analog isolation problems.
8
NC
NC
7
3
PD1 CATHODE
IPD1 I PD2
6
PD2 CATHODE
PD1 ANODE
4
PD2 ANODE
5
CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to
prevent damage and/or degradation which may be induced by ESD.
1-418
5965-3577E